4 Place pH and chlorine electrodes in the electrode holders. 
 
5 Start the filter pump 
 
6 Verify that the installation is not leaking 
 
7 Calibrate pH and redox electrodes, consult the Standard automatic pH‐dosage manuals 
(only pH min) ‐ ZWMX2140 and the Standard automatic chlorine dosage ‐ ZWMX2152.  
If you have no bypass configuration, you should place two rubber caps ZFPX4640 in the 
electrode holders to prevent water from spraying out during configuration. 
 
8 Configure the set points for the installation. PH will be set to 7.4 and redox at 700 mV. 
After the primary startup, measure the pH and chlorine levels with a color method. Change 
the set point for redox if necessary (lower if chlorine levels are too high, increase if 
chlorine levels are too low).   Consult the following manuals: Standard automatic pH‐
dosage (only pH min) ‐ ZWMX2140 and Standard automatic chlorine dosage ‐ ZWMX2152.  
 
 
9 Place the chlorine and pH suction caps in the correct chlorine and acid tubes. Avoid 
letting the cap sink to the bottom of the tube. This way, the entire tube of chlorine or acid 
won't get pumped into the pool in case of an error. 
 
10 Start the installation by enabling the electricity for the pump and the dosage appliance.  
 
 
 
 
 
 
 