Gas Conversion - Frigidaire FGF316ASA Installation Instructions Manual

30" gas range
Table of Contents

Advertisement

30" GAS RANGE INSTALLATION INSTRUCTIONS
12. Make Sure Range is Level.
Level the range by placing a level horizontally on an oven rack.
Check diagonally from front to back, then level the range by
either adjusting the leveling legs or by placing shims under the
corners of the range as needed.
13. After installation is complete, make sure all
controls are left in the OFF position.
Model and Serial Number Location
The serial plate is located under the lift-up cooktop.
When ordering parts for or making inquires about your range,
always be sure to include the model and serial numbers and
a lot number or letter from the serial plate on your range.
Your serial plate also tells you the rating of the burners, the
type of fuel and the pressure the range was adjusted for when
it left the factory.
Before You Call for Service
Check to make sure the house fuses or circuit breakers for
your range are not blown or open. Refer to the Avoid Service
Checklist and operating instructions in your Owner's Guide. It
may save you time and expense. The list includes common
occurrences that are not the result of defective workmanship
or materials in this appliance.
Refer to the warranty in your Owner's Guide for our
toll-free service number and address. Please call or write
if you have inquiries about your range product and/or
need to order parts.
Care, Cleaning and Maintenance
Refer to the Owner's Guide for operating and cleaning
instructions.
If removing the range is necessary for cleaning or maintenance,
shut off gas supply. Disconnect the gas and electrical supply.
If the gas or electrical supply is inaccessible, lift the unit
slightly at the front and pull out away from the wall. Pull only
as far as necessary to disconnect the gas and electrical
supply. Finish removing the unit for servicing and cleaning.
Reinstall in reverse order making sure to level the range and
check gas connections for leaks. See Anti-Tip Instructions for
proper anchoring instructions.

Gas Conversion

This range was adjusted for Natural or LP/Propane gas, as
specified on the serial plate.
Your regulator is in one of the two locations shown.
Do not remove the Pressure Regulator.
(For Models with Electric Ignition or Standing Pilot)
1a. Convert the Pressure Regulator
Self-Cleaning Electric Ignition Models
a. Unscrew the cap from the pressure regulator. Be sure
spring stays in place.
b. Turn the cap to the desired setting (see illustration below).
c. Replace the cap of the regulator. The letters corresponding
with the type of gas being used should be visible on the
exposed end of the cap.
1b.Convert the Pressure Regulator
Non Self-Cleaning Electric Ignition Models
a. Using a screwdriver or coin, turn the cap counterclockwise
to release from the pressure regulator. Be sure the O-ring
gasket stays in place.
b. Turn the cap over and place into the slots. Turn clockwise
to lock in position. The letters corresponding with the type
of gas being used should be visible on the exposed end
of the cap.
9

Hide quick links:

Advertisement

Table of Contents
loading