STARTING GAS BURNER
1. Be sure cock on combination valve is in "OFF" position for 5 minutes.
2. Open gas cock on combination valve to "ON" position.
3. Turn to electric switch.
4. Set room thermostat above room temperature.
5. Burner will light.
6. Set room thermostat to temperature desired.
FIG. 16-1C – ADAMS GAS BURNER EXPLODED ASSLY-
HP225 BPS
FIG. 16-1D ADAMS GAS BURNER PARTS LIST
HP225 BPS
Ref.
DESCRIPTION
1
Top Housing
2
Thermocouple
2
Sensor Probe
3
Pilot Burner
4
Pilot Orifice (Nat.)
4
Pilot Orifice (Prop.)
5
Ignition System
6
Transformer (20 V.A.)
7
Relay
8
Terminal Block
9
Air Door
10
Bottom Access Door
11
Slide Tray Assembly
12
Manifold
13
Pedestal (Not Shown)
14
Burner Casting
15
Insulating Boot
16
Pilot Shield
17
Electrode (3 inch)
18
Combination Valve (Nat.)
18
Combination Valve (Prop.)
19
Pipe Nipple
20
Main Orifice (Specify Size)
21
Adjustable Orifice Assembly
22
Bottom Housing Assembly
23
Mounting Flange (Optional)
24
Motor/Blower Assembly
25
APR Module (Optional)
26
Extension Sleeve (Not Shown) 7581-1A-BL
27
Ignition Wire (30 inch)
28
Sensor Wire (30 inch)
23
HP-225 BPS
7582-GN
----------
12003
J 124 DDA
5221 (.021)
3215 (.015)
EPI-100 or EPI
AT 20 A
R 8222 A 1002
7586-3
7582 A
7587 B
7586 D
7015 D-6
7584
7583-1
846
12005
7583-5A
SX 242 NS
SX 242 LS
50001-6-3 ½
172
6481
7581 B
7585
7586-2A
----------
7803
7852-2