MAINTENANCE PROCEDURE
9.
Install the inspection cover (A).
METHOD FOR CHANGING OIL IN MOTOR-GENERATOR CASE, CLEAN OIL FIL-
TER
•
Immediately after the engine is stopped, its parts and oil are still very hot, and may cause burn in-
jury. Wait for the temperature to go down, and then start the work.
•
Park the machine on a firm level ground and change oil.
Perform the oil replacement of motor-generator case and cleaning of oil filter according to the following table.
Item
Item
Replacement of oil
Motor-
generator
Cleaning of filter
4-64
k
k
WARNING
Type of oil
Power train oil TO10
(Komatsu genuine)
-
Replacement or cleaning
Refill capacity
Every 1 years or every
6.5 ℓ
1000 hours whichever
-
MAINTENANCE
interval
comes sooner