Page 2
® respective companies. The information in this document incorporates proprietary rights and is not to be duplicated wholly or in part without the express written permission of Regal Beloit Corporation and / or Regal Beloit America, Inc. March 2016/USA...
SAFETY Safety is emphasized throughout this user manual. These are safety alert symbols and signal words. They alert the user to potential per- sonal injury hazards. Obey all safety messages to avoid possible injury or death or damage to equipment and other property. DANGER DANGER DANGER indicates a hazardous situation which, if not avoided, will...
Introduction The VGreen 085 is a premium efficiency variable speed motor that ® provides tremendous program flexibility in terms of motor speed and time settings. The variable speed VGreen 085 is intended to enable running at the lowest speeds needed to maintain a sanitary environment, which in turn minimizes energy consumption.
Page 6
If power is connected to the VGreen 085 motor, pressing any of the following buttons referred to in section 2 could result in the motor starting. Failure to recognize this could result in personal injury or damage to equipment. Note: The START button must be pressed for the VGreen 085 to operate.
• Ability to configure freeze protection temperature. • Ability to view actual speed and power of the VGreen 085 in real time. • Ability to adjust the VGreen 085 motor speed in 25 RPM increments (to fine tune flow for certain pool installations). •...
Quick Start Guide (User-defined custom schedule) A VGreen 085 user can set the program DURATION and SPEED for STEP 1, STEP 2, STEP 3 & OVERRIDE keys. NOTE: VGreen 085 must be Stopped (Press STOP Key) for program- ming DURATION and SPEED of the STEP 1, STEP 2, and STEP 3 keys.
Page 9
5. Press STEP 2, STEP 3, or OVERRIDE key. Repeat steps 1- 4 to program the corresponding DURATION and SPEED for each button. 6. Press START to run the VGreen 085 based on the pro- grammed 24 hour schedule. 7. Pressing the STOP button will stop the VGreen 085. NOTE: The VGreen 085 can only be set to operate on a 24-hour sched- ule.
Overview NOTICE The VGreen 085 can and should be optimized to suit individual pool conditions. Specific conditions including pool size, other devices, features, and environmental factors can all impact the optimal settings. Program customization may require some trial-and-error to determine the most satisfactory settings as dictated by the conditions.
Wiring The VGreen 085 controller must be wired according to the locally adopted version of the NEC. A licensed, qualified electrician should complete the wiring for this product. Failure to comply with this may result in death, serious personal injury or property damage. The VGreen 085 controller must be wired according to the locally adopt- ed version of the NEC.
Page 12
Power should be turned off when installing, servicing, or repairing electrical components. Observe all warning notices posted on the existing equipment, VGreen 085, and in these installation instructions. EARTH (RED OR WHITE) (BLACK) EARTH 115V POWER SOURCE Figure 3: Mains Connection Diagram...
Page 13
VGreen 085 Controller UI DIGITAL INPUT CONNECTOR Automation System or J202 Solar System Controller STEP 1 (pin 1) STEP 2 (pin 2) STEP 3 EXTERNAL SUPPLY (pin 3) Vac or OVER RIDE (pin 4) COMMON (pin 5) External Supply Range: 18-30V AC (24V AC+/- 20%) 9-30V DC (12/24V DC +/- 20%) Figure 4: Wiring Diagram for Digital Inputs...
User Interface Operation LED and Function Overview V-Green 165 UI LED Indication and respective functionalities V-Green 165 UI LED Indication and respective functionalities Key
f or
L EDs Key
f or
L EDs Solid
O N
I ndication Solid
...
User Interface Key Pad Overview If power is connected to the VGreen 085 motor, pressing any of the following buttons referred to in this section 6.2 could result in the motor starting. Failure to recognize this could result in personal injury or damage to equipment. 1.
Page 16
Button Duration Speed (In Hours) (In RPM) STEP 1 3100 STEP 2 2600 STEP 3 1600 OVERRIDE 3450 Table 3: Factory default schedule Schedule Tables Use the tables below to record a personalized operating schedule. Recording the planned schedule in the table below will make the pro- gramming process easier and will help the user remember the custom settings in case of inadvertent loss of schedule.
Setup #2 Step 1 Step 2 Step 3 Duration Speed Table 4: Custom Schedule Running VGreen 085 from Keypad If power is connected to the VGreen 085 motor, pressing any of the following buttons referred to in this section 6.4 could result in the motor starting. Failure to recognize this could result in personal injury or damage to equipment.
Page 18
4. This sequence will then repeat for STEP 2 and then STEP 3 with- out the VGreen 085 stopping. 5. At the end of STEP 3, the VGreen 085 will wait if necessary for the completion of the 24-hour schedule. During this waiting period (if applicable), all of the “active step LEDs”...
OVERRIDE The VGreen 085 is equipped with an OVERRIDE feature, which can be engaged to temporarily run at higher or lower speeds ranging between 600 to 3450 RPM. Once the OVERRIDE duration has elapsed, the VGreen 085 will automatically return to the programmed schedule. 1.
NOTE: Pressing/Holding OVERRIDE key for more than three (3) seconds will cancel OVERRIDE mode. NOTE: During the OVERRIDE mode, the VGreen 085 will not start with the priming sequence. NOTE: It is recommended that you do not set the OVERRIDE duration to 0 HRS.
Page 21
2. Press the UP (+) or DOWN (-) arrows to set the desired delay time after which the 24-hour schedule should start. The Schedule Advance mode will automatically start after the desired delay time is selected. The Schedule Advance mode can be canceled by press- ing the STOP key.
Key Lockout Key lockout will not prevent the motor from being stopped by pressing the STOP button. If the motor is operating in “key lockout” mode, and being controlled through a digital or serial input, the motor will only temporarily stop (4 min.) it will then restart. The VGreen 085 user interface has a “key lockout”...
Motor Pause The VGreen 085 user interface has a “motor pause” feature that will allow the user to temporarily stop the VGreen 085 for maintenance work without disrupting the 24 hour schedule (i.e., for backwashing the filter). If the VGreen 085 is currently running, the user can press and hold the START button for more than three (3) seconds and the VGreen 085 will stop and remain off until the user presses and holds the START button again for more than three (3) seconds.
6.10 Reset Factory Defaults The VGreen 085 user interface has a “Reset to Factory Defaults” feature to restore the schedule settings back to the original values programmed at the factory. The user must press and hold the STOP and OVERRIDE buttons for three (3) seconds to reset the settings back to factory defaults.
Control with Digital Inputs The user can run the VGreen 085 at the programmed STEP 1, STEP 2, STEP 3, or OVERRIDE speeds by utilizing the four digital inputs. STEP 1, STEP 2, STEP 3, or OVERRIDE are equivalent to Digital Input 1, 2, 3 or 4 respectively.
NOTE: If no digital input is detected, the VGreen 085 will automatically start the 24 hour schedule if the START key was pressed prior to the application of a digital input. Access to these terminals is in close proximity to the mains connectors which carry line voltage capable of causing personal injury or damaging the equipment if contact is made.
Care and Maintenance The VGreen 085 is both reliable and robust in harsh environments. However, this product does contain electronics that are cooled by a fan mounted to the VGreen 085. In order to ensure optimum reliability of this product, it is recommended to clean the fan inlet on the back of the VGreen 085 once a month.
Page 28
Below is the behavior of the FAULT LED when a FAULT is detected: When a FAULT is present, and the motor is not running, only the FAULT LED and power LED will illuminate. When a FAULT is present, and the motor is running, then the FAULT LED will illuminate.
Specifications Overall Ratings Input Voltage 115 Vrms nominal Input Current 0.4 - 10.0 Arms Input Frequency Single phase, 60/50 Hz Control Terminals 18-30V AC (24V AC+/- 20%) or 9-30V DC (12/24V DC +/- 20%) Auxiliary Load Terminals Maximum Continuous Load 0.85 THP (Total Horse Power) Speed Range 600 - 3450 RPM...
Troubleshooting Guide Diagnosing certain symptoms may require close interaction with, or in close proximity to, components that are energized with electricity. Contact with electricity can cause death, personal injury, or property damage. When trouble shooting the VGreen 085, diagnostics involving electricity should be cared for by a licensed professional. Symptom Possible Causes Potential Solutions...