Page 1
EUP6 - EUP11 Instantaneous gas water heater User, Installation and Maintenance Manual...
Page 2
The energy label carries the information regarding the product’s energy efficiency characteristics. In this way the end consumer can identify and compare similar products and can make informed choices regarding high efficiency appliances. Morco Morco EUP6 Morco Morco EUP11 kWh/annum GJ/annum...
When the product has reached the end of its service- able life, it shall be disposed of in an environmentally WARNING friendly way and disposed of according to the regu- lations in force. This booklet contains information relevant to Separate collection and recycling of the product avoid the user as well as the installer.
The appliance does not store hot water. The flow of the water through the appliance can be adjusted from 3 to 6 litres per minute (EUP6 model) and 5.5 to 11 litres per minute (EUP11 model) and this corresponds to the temperature of the incoming water being increased by 50°C or 25°C respectively.
Page 5
1. OPERATION A = Gas economizer on/off ● off position pilot position Min temp minimum gas level Max temp maximum gas level B = Water temperature selector Minimum Temperature Maximum Temperature fig. 1 1.a. Function - Rotate Knob A towards the large flame ( ), during rotation it is The water heater is designed to produce instantaneous hot necessary to keep the knob pressed down lightly until the final water.
Page 7
1.d Components EUP6 fig. 3 Combustion products safety sensor Flue diverter hood Heat exchanger Burner Water control assembly Water temperature adjustment knob Gas valve 8a Gas inlet test point 8b Burner pressure test point Gas inlet 10 Gas adjustment screw - should not be adjusted...
(for EUP11) must be used and when it passes through combu- Wall mounting stible materials, a metal sleeve of Ø170mm must be used to allow an air gap of 25 mm. Part codes FTFCT (for EUP6) and Warning FTFCTRIMG101 (for EUP11).
- The diameter of the flue terminal must match that of the water due to the technical issue being resolved thus allowing the water heater (90 mm for EUP6 and 110mm for EUP11) heater to operate as normal. - The overall flue length from the top of the water heater to the If the flue gas safety device is faulty it will need to be replaced top of the external flue must be at least 600mm.
4. MAINTENANCE 4.b Troubleshooting: problems and solu- tions To maintain the machine at maximum efficiency, have a Gas Safe For the best functioning of the water heater, to prolong its lifetime Engineer or other qualified personnel perform a maintenance and ensure that it is always safe, it should be inspected at least check at least once a year.
FOR THE ENGINEER STARTING UP THE APPLIANCE AND FINAL CHECKS Start the appliance by following the directions given in section insects and spiders webs. 1b, “Usage”, checking that the appliance is working correctly. Pay special attention to the colour of the flames ensuring there is no •...
Page 13
WINTERISATION Winterisation of Holiday Homes That Have a Water Heater Fresh water freezes at 0°C and expands by 9% with a significant force that will destroy: • Pipe work • Water heater components • Taps, and shower valves DRAIN DOWN If you leave fresh water in your caravan system over the winter you will run the risk of damage.
Page 14
(Installation and Use) act of 1998. The guarantee does not cover defects caused by lack of maintenance. Morco Products Ltd. warranty will cover parts and labour if the appliance has been fitted as part of the original equipment in a caravan holiday home or leisure accommodation vehicle.
Page 16
Supplied by Innovita Italy Distributed in U.K. by: MORCO PRODUCTS LTD Morco House Riverview Road Beverley East Yorkshire HU17 0LD ENGLAND Telephone Number: 01482 325456 Fax Number: 01482 212869 Web Address: www.morcoproducts.co.uk...
Need help?
Do you have a question about the EUP6 and is the answer not in the manual?
Questions and answers