Preventative Maintenance - Bambi VT Operator's Handbook Manual

Oil-free range
Table of Contents

Advertisement

6
8) Removing Housing Cover (VTS Models Only)
For routine maintenance it may be necessary to remove the top cover. Adhere to the
following procedure:
Models: VTS 75/75D, 150/150D, 200/200D
Disconnect from the mains power supply and release all the air from the compressor
and the air system.
Using the hex key provided, remove the 3 bolts fixing each end cover in place and
remove the end covers.
Remove the bolts holding the top cover in place.
Gently lift up the top housing.
Note !
Do not use excessive force as this will strain the electrical and air connections.
Carefully pull apart the electrical multi connector by squeezing the side clips and
gently pulling the connector apart. Do not use excessive force.
To release the air connections, push the connector collar in and simultaneously pull
the air tube out.
Reassembly is a reverse of the above but check that -
The air tubes are pushed fully home into the connector and seal
The electrical connector is secure
No wires or air tubes are trapped in the housing join
Models: VTS250/250D
Disconnect from the mains power supply and release all the air from the compressor
and the air system
Using the hex key provided, remove the 4 bolts fixing the top cover in place and
remove the top cover.

Preventative Maintenance

Operation
Drain Air Receiver
Replace Air Intake Filter
Check Pressure Relief Activation
Clean After Cooler Fins
Clean Ventilation Grilles
Check Piston Ring
Replace Air Dryer Filter
Desiccant Change
Coalescing Filter Element
Above are to be considered minimum frequency
Daily
Weekly
Annually
2 Years