ASSEMBLY
Installing control valve, fittings and hoses
1) First install the control valve/control lever assembly (A) Fig.9 to the beam
mounting plate (B) using 2 hex. bolts.
2) Install the fitting (C) Fig.9 to the side port of the control valve.
3) Install the fitting (D) Fig.9 to the port underneath the control valve.
4) Install the fitting (E) Fig.9 to the lowest port underneath the control valve.
5) Thread the hose (#1) Fig.9 to the fitting (C) Fig.9 and thread the other end of hose
(#1) Fig.10 to the fitting (A) Fig.10 on top of the pump.
6) Thread the hose (#2) to the fitting (E) Fig.9 and thread the other end of hose (#2)
to the fitting (B) Fig.10 at the front of the cylinder.
7) Thread the hose (#3) Fig.9 (the shortest hose with fittings) to the fitting (D) Fig.9
and thread the other end of hose (#3) Fig.10 to the fitting (C) Fig.10 at the rear of
the cylinder.
8) Slide the return hose (#4) Fig.9 & Fig.10 onto the return valve fitting (D) Fig.10 on
the axle/tank and slide the other end of hose (#4) Fig.9 onto the return valve fit-
ting at the rear of the control valve. Secure both ends of the hose by tightening
the hose clamps.
Note: Secure all hose threaded couplings to the control valve to 44-45 ft-lbs using a
torque wrench. Tighten all other threaded couplings to 47 ft-lbs using a torque wrench.
INITIAL SETUP BEFORE OPERATION

ENGINE OIL LEvEL

wARNING! This engine has been shipped from the factory without oil or very
little oil in the crankcase. Operating your engine without the correct amount of
oil can damage it. Oil crankcase capacity: 0.6 litres.
Always check the oil level before starting the engine, make sure the engine is
on a level surface. To check oil level;
1) Turn the oil gauge dipstick (A) Fig.11 counterclockwise, remove it and clean it with
a clean cloth.
2) Fully reinsert the oil gauge dipstick and pull it out to check the oil level.
3) If the oil level is halfway up the dipstick or below, refill with SAE 10W30 oil through
the dipstick hole until the oil level reaches 3/4 up the dipstick or until it reaches the
bottom lip of the dipstick hole as shown in illustration Fig.12.
4) Reposition the oil gauge dipstick and tighten it by turning clockwise.
LOG SPLITTER ASSEMBLY
& INITIAL SET-UP BEFORE OPERATION
Figure 9
Figure 10
Figure 11
Figure 12