20 | English
Indication
Meaning
No display shows:
– Battery capacity is
empty or very low.
– Battery is idle
– Battery temperature
> 80 °C
Display shows thermom-
70
%
eter and battery symbol:
– Battery is too hot
(between 50 °C–
70 °C). Battery can
be used in tool, but
not be charged.
– Battery is too cold
(under 0 °C)
Display shows flashing
warning, thermometer
and battery symbol:
– Battery is too hot
(between 70 °C–
80 °C). Battery can-
not be used in tool
and cannot be
charged.
2 609 932 876 | (5.11.15)
Measure
– Recharge bat-
tery.
– Move battery
to see status.
– Let battery
cool down
– Let battery
cool down
– Battery can be
used in tool but
cannot be
charged until it
warms up.
Battery will not
charge until the
temperature is
within limits. Let
battery cool
down.