DRT2000 and DRC2000 Direct-Vent Fireplaces
Burn-in Period
The fi rst few times this fi replace is operated, there will be an odor from the curing of paint and the burning off of the
lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few
days.
NOTE: Ventilate the site during the burn-in period. The resulting odor and haze may set off a smoke detector. Do not
operate the blower during the burn-in period.
A white fi lm may develop on the glass front during the fi rst few fi res as part of the burn-in period. The glass
should be kept clean during the burn-in period to prevent the fi lm from baking on—making it very diffi cult to
remove (Cleaning the glass door on Page 57).
Accessing the Control Compartment
NOTE: If the door is diffi cult to open/close, remove it as instructed and straighten the door tabs (Figure 46).
1. Access the control compartment (Figure 34) by holding the control compartment door by the top and gently
Closing the Control Compartment
1. Swing the door gently up and then lift and set the door so it catches in the upright, closed position.
Removing the Control Compartment Door
1. Remove the bottom, left screw (Figure 45) inside the control compartment securing the control compartment
2. Position the left side door tab (Figure 46) out of the tab groove and align it with the vertical slot (Figure 45).
3. Lift the left side of the control compartment door with the tabs in the vertical slot until the tabs clear the slot,
4. Pull the door to the left to disengage the right side door tabs, and remove the door. Store the control
Figure 42 - Control compartment door slots
Gas Controls
The standard controls for fi replace operation are located in the control compartment, below the glass door
(Figure 34). Optional control switches are also available.
Millivolt and electronic gas control systems operate differently. Before lighting and operating the fi replace determine
if it is a millivolt or electronic system:
Familiarize yourself with the gas control valve and the lighting procedure (Pages 64-67).
Millivolt Fireplaces
Detailed lighting instructions are found on Pages 64-67. Also, millivolt fi replace lighting instructions are found on
the pull-out lighting instructions attached to the gas control valve.
When the pilot is lit, the main burner can be turned ON/OFF using a wall switch, remote control, optional on-unit
rocker switch (FRS), or wall thermostat.
If the millivolt fi replace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or
wall thermostat) and the pilot is lit, the fi replace main burner can be turned ON/OFF using the optional switch.
50
lifting it up, then rotating it away from the fi replace.
door. Retain the screw for later reinstallation.
disengaging the left side of the door from the fi replace.
compartment door in a secure location until reinstallation.
Vertical
slot
Tab
groove
Tab pivot
hole
Millivolt Fireplaces (Figure 1)
Electronic Fireplaces (Figure 2)
Figure 43 - Control compartment door tabs
Screw
hole
Operation
900004-00, 03/2017