Wall Finishes / Surrounds / Mantels; Installation Preparation - Superior DRT2000 Series Installation And Operation Instructions For

Direct-vent gas fireplaces
Hide thumbs Also See for DRT2000 Series:
Table of Contents

Advertisement

Innovative Hearth Products
DRT2000 and DRC2000 Direct-Vent Fireplaces
Table 10 - Combustible Shelf Height—Rear Vent
Figure 6 - Combustible Side Clearances
At 6" minimum
side wall
clearance, a
At 6" minimum
side wall clearance,
combustible
a combustible wall
wall can project
can project to any
to any length.
length.
6" (152 mm)

Wall Finishes / Surrounds / Mantels

NOTE: Combustible wall fi nish materials and/or surround materials must not be allowed to encroach the area defi ned
by the fi replace front face (black sheet metal). Never allow combustible materials to be positioned in front of or
overlapping the fi replace face (Figure 41).
Non-combustible materials, such as surrounds and other fi replace trim, may be installed on the fi replace face, but they
must not cover any portion of the removable glass panel or control compartment.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel (Figure 7). Mantels
constructed of non-combustible materials may be installed at any height above the fi replace opening. However, do
not allow anything to hang below the fi replace hood.
Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above the
fi replace.
NOTE: To avoid heat-related fi nish damage, we recommend the use of high temperature paint (rated 175° F or higher) on
the underside of the mantel.

INSTALLATION PREPARATION

The fi replace is shipped with all gas controls and components installed and pre-wired. Before installing the fi replace,
follow these steps:
1. Remove the shipping carton, and retain the front of the carton (used to protect the fi replace during construction).
2. Remove the shipping pad, exposing the front glass door.
3. Remove the glass door (Page 55).
NOTE: Place the glass door on the shipping carton to protect its surface.
Model
Secure Vent
33" Models
34" (864 mm)
35" Models
36-1/4" (921 mm)
40" Models
40-1/2" (1029 mm)
45" Models
45-1/2" (1156 mm)
Top View of
Top View of
Fireplace
Fireplace
Combustible materials
o
45
Combustible Materials
allowed in shaded area
o
3-1/2"
45
Allowed In Shaded Area
"Safe Zone".
(89 mm)
3-1/2"
"Safe Zone"
(89 mm)
Combustible walls
Combustible Walls
shown in dark gray
shown in dark gray
Combustible mantel
Combustible mantel legs may
legs may project
project beyond either side
beyond either side of
of the fireplace opening
the fi replace opening
as long as they are kept
as long as they are kept
within the shaded area
within the shaded area
illustrated here.
illustrated here.
Rear Vent with two 90° Elbows
®
Secure Flex
®
(fl ex elbow)
34" (864 mm)
36-1/4" (921 mm)
40-1/2" (1029 mm)
45-1/2" (1156 mm)
Figure 7 - Mantel Height
18 (457)
16 (406)
14 (356)
12 (305)
10 (254)
8 (203)
12
(305)
10
(254)
in. (mm)
3" clearance from shelf to
top of fi replace and/or vent
pipe, whichever is higher
Shelf Height
(see table)
Mantel depth
4
8
Hood
(102)
(203)
6
2
Fireplace
(152)
(51)
General Information
900004-00, 03/2017
No
combustibles
or insulation
in the shaded
area between
the appliance
and the shelf
above it.