3. Other Alarm Visual and Audible Indicators

Operational Mode
normal (standby)
Test (button press when
no alarm condition is
present)
Smoke alarm Memory
(unit has experienced a
smoke alarm event within
the last hour)
Smoke alarm Hush Mode,
(Hush®
control)
Smoke alarm Hush Mode
canceled
initiating alarm,
(Multiple alarms in an
interconnected system)
6
Visual Indications
AC power: Green LED on continuously
during light conditions, or blink every 60
sec during dark conditions.
DC power: Green LED blink approx
every 60 sec.
• 4 patterns of Red/Amber/Green.
• Test: Red LED blinks in time with alarm
pattern. Strobe flashes every second.
• Green LED fade on/off at test complete
Red and Amber LED alternate on 1 sec,
every 10 sec.
Red LED blinks every 2 sec.
None
Green LED blinks once per sec indicating
that this is the unit initiating the alarm
in an interconnected, multiple alarm,
system.
Audible Indications
• Button press sound
• Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
• 3 long beeps, Voice "Fire!", 3 long
beeps, Voice "Test Complete,"
Power on/reset sound.
• Voice "Test Canceled" if button
pushed before test sequence
begins.
After button push: "Smoke previously
detected" only on the initiating
alarm unit.
After button push: "Hush Mode
Activated." Smoke alarm pattern
stops. (If there is too much smoke to
allow Hush: Voice "Too Much Smoke,
Alarm cannot be Hushed" Smoke
alarm pattern continues.)
Voice message "Hush Mode
Canceled."
Unit in Smoke alarm mode.
Action/Note:
Perform Test/Hush button press
once a week to verify proper alarm
operation
* Push/release button before the
countdown ends to cancel test.
Push test button to clear Alarm
Memory. NOTE: standard test
sequence will follow. (Push/release
button again to cancel test).
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm.
When smoke levels drop below the
alarm threshold, the voice message
"Hush Mode Canceled" will occur .
During alarm, the Initiating alarm
green blinks will occur in between
the red blinks.