waRninG: DO nOT uSE an OpEn FLaME TO TEST yOuR aLaRM, yOu cOuLD DaMaGE
THE aLaRM OR iGniTE cOMBuSTiBLE MaTERiaLS anD STaRT a STRucTuRE FiRE.
STROBE SyncHROnizaTiOn
This strobe alarm will automatically synchronize (flash at the same time) with other
P4010ACLEDxx strobes that are part of the interconnected system. Synchronization will take up
to 20 seconds when in alarm. nOTE: The alarms will not synchronize during test mode.
SMOkE aLaRM MEMORy
If a unit experiences a smoke alarm event, then the condition clears and the unit stops alarming,
the unit will give a visual (LED) indicator that a previous alarm has occurred within the last hour.
See the Other Alarm Visual and Audible Indicators table.
aMBiEnT LiGHT SEnSinG
In low light ambient conditions, the green LED ring fades to off, and then blinks approx every 60
seconds. This unit samples the ambient light conditions of the alarm's location and, if possible,
determines a Night / Day cycle. A valid Night / Day cycle will delay unit chirps during the night
until the next Day cycle begins.
cHiRpinG
When chirping begins during the next Day cycle, you can temporarily silence End of Unit Life
chirps by pressing the Test/Hush button. Low Battery chirps cannot be silenced.
If a valid Night / Day cycle has not been established because the unit is located in either a
constantly dark or lighted location, the chirps mentioned above will not be delayed at night.
Moving the unit to a different location might allow the unit to determine a valid Night / Day cycle.
waRninG: REpLacE uniT aS SOOn aS pOSSiBLE wHEn in EnD OF uniT LiFE OR
LOw BaTTERy MODE.