Download Print this page

Dial Temperature Control - Perlick HP24Z Use & Care Manual

Residential undercounter refrigeration
Hide thumbs Also See for HP24Z:

Advertisement

C-Series Models
Model
HC24RB
HC24BB
HC24WB
LED Functions
The following table describes LED Funtions
Defrost LED
Permanently on: defrost active
Flashing: manual defrost active
Off: otherwise
Evaporator LED
Permanently on: fans active
Off: otherwise
Aux LED
Permanently on: Aux output
active
Off: otherwise
NOTE: When switched on, the device performs a Lamp Test;
the display and LEDs will flash for several seconds to check that
they all function correctly.

DIAL TEMPERATURE CONTROL

ADA-Compliant Models
(Excludes ADA Freezer - HA24F models use digital controller
found on page 5)
3
2
1
Figure 3. Dial Temperature Controller
8 | perlick.com/residential
PERLICK RESIDENTIAL UNDERCOUNTER REFRIGERATION USE & CARE GUIDE
TOUCH-SCREEN CONTROL OPERATION - FREEZER MODELS
Temp Range
33° - 42° F
33° - 48° F
45° - 65° F
Alarm LED
Permanently on: alarm active
Flashing: alarm acknowledged
Off: otherwise
Compressor LED
Permanently on: compressor active
Flashing: a delay, a protection or a
locked start-up
Off: otherwise
°C LED
Permanently on: display the
temperature
Off: otherwise
4
5
6
COLD
OFF
Use a straight slot screwdriver to adjust the dial temperature
control. The control is located at the top rear panel of the
cabinet. Approximate temperature ranges are as follows:
ADA-Compliant Series
Model
HA24RB
HA24BB
HA24WB
Adjust the temperature as follows:
Colder Temperature:
Turn the adjusting screw clockwise (to the right).
Warmer Temperature:
Turn the adjusting screw counterclockwise (to the left).
Temperature Control OFF:
Turn the adjusting screw completely counterclockwise to the
OFF position until a click is heard.
NOTE: The condenser fan motor turns off with the compressor.
Temp Range
33° - 42° F
35° - 48° F
45° - 65° F

Hide quick links:

Advertisement

loading