1-6. Insulation Tests

On completion of disassembly and repair, carefully measure the insulation resistance and conduct a dielectric
strength test.
Insulation resistance: 7 M Ω or more with 500 V DC megohm tester
Dielectric strength test: AC 4,000 V/1 minute with no abnormalities .................... 220 V --- 240 V products
1-7. No-load Current Value
After no-load running for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
AC 3,500 V/1 minute with no abnormalities .................... 110 V --- 127 V products
110
220
2.6
1.2
230
240
1.2
1.2