Insulation Tests; No-Load Current Value - Hitachi PDA-100K Technical Data And Service Manual

Hitachi disc grinder technical data and service manual
Table of Contents

Advertisement

(5) For other countries
Stator
Gray
Stator
Gray

8-6. Insulation Tests

On completion of disassembly and repair, carefully measure the insulation resistance and conduct a dielectric
strength test.
Insulation resistance: 7 MΩ or more with 500 V DC megohm tester
Dielectric strength test: AC 4,000 V/1 minute with no abnormalities .................... 220 V --- 240 V products

8-7. No-load Current Value

After no-load running for 30 minutes, the no-load current value should be as follows.
Voltage (V)
Current (A) max.
Switch
Black
Brown
1
3
Cord
Black
Blue
Connector
AC 2,500 V/1 minute with no abnormalities .................... 110 V --- 127 V products
110
220
3.0
1.6
230
240
1.8
1.7
--- 14 ---