(7) Connect the internal wires of Stator (A) [10] correctly as shown in Fig. 6 and Fig. 7.
(8) Connect each internal wire correctly as shown in Fig. 7 being careful not to put them between the parts.
OFF side
ON side
Insert the terminal securely then push
and fold the terminal toward the outside
of the housing as much as possible.
Brush Holder [40]
Bottom of the housing
(9) When replacing the Gear Cover Ass'y [3], lubricate the needle bearing part with mixed oil.
Mixed oil: A mixture of Hitachi Power Tool Grease No. 2 (Unilube No. 00 Code No. 939302 is recommended)
and turbine oil
Mixture ratio ......... 1:1 (weight ratio)
Internal wire from Cord [54]
Machine Screw (W/Washer) M3.5 x 6 [48]
Guide plate
Internal wire from Stator (A) [10]
Internal wire from Noise Suppressor [45]
Internal wire coming from
the Noise Suppressor [45]
Switch (1P Screw Type) [49]
: Tail Cover (A) [35]
Machine Screw (W/Washer) M3.5 x 6 [48]
Fig. 6
Fig. 7
Quantity ........... 0.5 cc