How to connect your extended power cables

Items to prepare
Tools
Crimping pliers
Spec
MH-14
Shape
1. As shown in the figure, peel off the shields from the rubber/wire
of the power cable.
- Peel off 20 mm of the wire shields of the tube installed already.
• F or information about the power cable specifications for indoor and
outdoor units, refer to the installation manual.
• A fter peeling off the tube wire, you must insert a contraction tube.
2. Insert both sides of core wire of the power cable into the connection sleeve.
3. Using a compressor, compress the two points and flip it over
and compress another two points in the same location.
- The compression dimension should be 8.0.
- After compressing it, pull both sides of the wire to
make sure it is firmly pressed.
4. Wrap it with the insulation tape twice or more and position your contraction
tube in the middle of the insulation tape.A total of three or more layers of
insulation is required.
5. Apply heat to the contraction tube to contract it.
6. After tube contraction work is completed, wrap it with the
insulation tape to finish.
- Make sure that the connection parts are not exposed to outside.
- Be sure to use insulation tape and a contraction tube made of approved
reinforced insulating materials that have the same level of withstand voltage
with the power cable.(Comply with the local regulations on extensions.)
• I n case of extending the electric wire, please DO NOT use a round-shaped pressing socket.
- Incomplete wire connections can cause electric shock or a fire.
Connection sleeve (mm)
20xØ7.0(HxOD)
English-49
Insulation tape
Contraction tube (mm)
Width 18 mm
50xØ8.0(LxOD)
Power cable
Connection sleeve
(Unit: mm)
20
20
20
60
120
180
Wire tube power cable
20
Comp. dim.
Compress it 4 times
5 mm
Insulation tape
40 mm
Contraction tube
Insulation tape