Advertisement

Quick Links

user & installation manual
user & installation manual
This manual is made with 100% recycled paper.
RC_BORACAY_IB&IM_EN_DB68-05679A-00.indd 1
Air Conditioner
Air Conditioner
imagine
the possibilities
imagine
the possibilities
Thank you for purchasing this Samsung product.
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
DB68-05679A-00
AR✴✴KPFH✴✴ Series
AR✴✴FSSSBWK Series
AR✴✴FSSSCUR Series
2/1/2016 2:18:36 PM

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AR KPFH Series

  • Page 1 This manual is made with 100% recycled paper. imagine the possibilities imagine the possibilities Thank you for purchasing this Samsung product. Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DB68-05679A-00 RC_BORACAY_IB&IM_EN_DB68-05679A-00.indd 1...
  • Page 2 Features of your new air conditioner 2-step cooling 2-step cooling function will quickly cool the room to reach the set temperature and then it will adjust the fan speed and air flow direction automatically to help you stay comfortable and refreshing.
  • Page 3: Table Of Contents

    Contents Preparation Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Checking before use .
  • Page 4: Safety Precautions

    If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe WARNING personal injury or death.
  • Page 5 Do not install this appliance near a heater, inflammable material. Do not install this appliance in a humid, oily or dusty location, in a location exposed to direct sunlight and water (rain drops). Do not install this appliance in a location where gas may leak. ...
  • Page 6 Safety precautions CAUTION FOR POWER SUPPLY When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker.  Failing to do so may result in electric shock or fire. WARNING FOR USING If the appliance is flooded, please contact your nearest service center.
  • Page 7 Do not insert your fingers or foreign substances into the outlet when the air conditioner is operating.  Take special care that children do not injure themselves by inserting their fingers into the product. Do not touch the air flow blade with your hands or fingers during the heating operation.
  • Page 8 Safety precautions CAUTION FOR USING Do not place objects or devices under the indoor unit.  Water dripping from the indoor unit may result in fire or property damage. (example electrical appliances) Check that the installation frame of the outdoor unit is not broken at least once a year.
  • Page 9 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
  • Page 10: Checking Before Use

    Checking before use Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. Mode Indoor temperature Outdoor temperature Indoor humidity Cooling ˚C~32 ˚C 15 ˚C~43 ˚C Relative humidity 80% or less Heating 27 ˚C or less...
  • Page 11: Checking The Name Of The Parts

    Checking the name of the parts Your air conditioner may slightly look different from illustration shown below depending on your model. Main parts Room temperature sensor Air intake Air filter (under the panel) Air flow blade (up and down) Air flow blade Blade pin lever (left and right) Display...
  • Page 12: Checking The Remote Controller

    Checking the remote controller • Point the remote controller towards the remote controller receiver of the indoor unit. • W hen you properly press the button on the remote controller, you will hear beep sound from the indoor unit and a transmit indicator( ) appears on the remote controller display. Remote controller buttons Vertical air swing Activate/Deactivate vertical air flow blade movement automatically Power Mode Turn on/off the air Set one of the 5 operating modes conditioner Temp + –...
  • Page 13 Checking the remote controller Remote controller display Transmit indicator Operation mode Low battery indicator indicator Set temperature/ Time (for Fan speed indicator Timer option) indicator good'sleep indicator Vertical air swing indicator Options indicator Settings indicator • Make sure that the water does not get to the remote controller. • The following function are displayed on the remote controller display but not supported in this model. - Quiet/ Virus Doctor ( )/ d'light Cool / Usage / Filter Reset / Display When turning off and turning on the remote controller, the Timer, Options and Settings set before turning off the •...
  • Page 14: Basic Function

    Basic function Basic operation is an operation mode that can be selected by pressing the Mode button. Auto In Auto mode, the air conditioner will automatically set the temperature and fan speed depending on the room temperature. Cool In Cool mode, the air conditioner will cool your room. You can adjust the temperature and the fan speed to feel cooler in hot season.
  • Page 15 Basic function Press the button to turn on the air conditioner. Press the button to set the operating mode. • Each time you press the Mode button, the mode will change in order of Auto, Cool, Dry, Fan and Heat. Press the button to adjust the temperature. Auto You can adjust the set temperature by 1 °C within the range of 16 °C~30 °C.
  • Page 16: Adjusting The Air Flow Direction

    adjusting the air flow direction Air flow can be directed to your desired position. Vertical air flow This function will allow you to adjust the air flow direction vertically . Press the button to make air flow blades vertically. f To keep the air flow direction in a constant direction, press the button again .
  • Page 17: Setting The On/Off Timer

    Setting the On/Off timer Setting the On timer When the air conditioner is off; 1 . Press the Timer button to select (On) . - (On) indicator will keep blinking and you can set the time . 2 . Press the button to set the time .
  • Page 18 Setting the On/Off timer Setting the Off timer When the air conditioner is on; 1 . Press the Timer button to select (Off) . - (Off) indicator will keep blinking and you can set the time . 2 . Press the button to set the time .
  • Page 19: Mode

    mode For a comfortable sleep, the air conditioner will operate in 3 stages in order of Fall asleep  Sound sleep  Wake up stage . When the air conditioner is operating in Cool/Heat mode; 1 . Press the Timer button to select ( ) indicator will keep blinking and you can set the time .
  • Page 20: 2-Step Cooling Function

    2-Step cooling function 2-Step Cooling function will set the air conditioner to cool the room quickly to reach the set temperature when the indoor temperature is higher than the set temperature, and then the air conditioner will automatically operate in Dry mode when indoor temperature reaches set temperature .
  • Page 21: Using The Fast Function

    using the Fast function You can set the Fast function to provide fast and powerful cooling. When the air conditioner is operating in Cool mode; 1 . Press the Options button . or Options button until (Fast) indicator starts to blink . 2 .
  • Page 22: Using The Single User Function

    using the Single user function This function will reduce the energy usage while the air conditioner is operating in Cool mode. When the air conditioner is operating in Cool mode; Press the Single user button . - (Single user) indicator will be displayed on the remote controller display . Then will be displayed on the set temperature indicator part for few seconds and Single user function will begin .
  • Page 23: Using The Auto Clean Function

    using the auto Clean function Auto clean function will minimise the moisture inside of the indoor unit. Activate this function to help provide you with clean air. When the air conditioner is operating; 1 . Press the Settings button . 2 .
  • Page 24: Cleaning The Air Conditioner

    Cleaning the air conditioner • Make sure to turn off the power of the indoor unit and cut-off the power supply before cleaning the air conditioner. CAUTION Cleaning the indoor unit Clean the product with a tepid damp cloth.  Remove the dust accumulated in the gap of the product with a soft ...
  • Page 25 Removing the Air filter Grab the handle and lift it up. Then, pull the Air filter towards you and slide it down. Air filter Cleaning the air filter Washable foam based air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. Open the panel and put the Air filter out. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, rinse it with running water.
  • Page 26: Maintaining The Air Conditioner

    Maintaining the air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and cut-off the power supply.
  • Page 27: Troubleshooting

    Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner • Check power status and then operate the air conditioner again. does not work at all. • P lug in or switch on the circuit breaker and then operate the air conditioner again. • Ensure Isolator is switch on. • C heck if you have set the Off Timer. Operate the air conditioner again by pressing the Power button.
  • Page 28 PROBLEM SOLUTION Fan speed • C heck if you have selected Auto/Dry/Fast/ mode. In adjustment is not these mode, fan speed is set to Auto and you cannot adjust the fan working. speed. Remote controller is • Check if your batteries are depleted. not working. • Make sure nothing is blocking your remote controller sensor. • C heck that there are strong lighting apparatus near the air conditioner.
  • Page 29: Safety Precautions

    In order to help prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact  SAMSUNG’s technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. These operations ...
  • Page 30: Choosing The Installation Location

    Installing the unit IMPORTANT: W hen installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. Upon receipt, inspect the product to verify that it has not been damaged during transport. f If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer.) After completing the installation, always carry out a functional test and provide the instructions on how to operate the air f...
  • Page 31 Choosing the installation location Outdoor Unit Where it is not exposed to strong wind  Well ventilated and dustless places  Where possible keep out of sunlight and rain  Where neighbors are not annoyed by operation sound or hot air f Solid wall or support that prevents vibration and is strong enough to hold the product weight  Where there is no risk of flammable gas leakage  When installing the unit at a high place be sure to fix the unit legs  3 m or more away from the TV or radio (to prevent the screen from being distorted or noise from being generated) ...
  • Page 32 Space Requirements for Outdoor Unit When installing 1 outdoor unit  Figure Description Top view Side view Air intake Air outlet Air intake Air outlet Air flow direction  (Unit : mm)  W hen the air outlet is opposite  W hen the air outlet is towards the  W hen 3 sides of the outdoor unit the wall wall are blocked by the wall 150 or more...
  • Page 33: Accessories

    Choosing the installation location (Unit : mm)  W hen the walls are blocking front and the rear side of the outdoor  W hen the upper part of the outdoor unit and units the air outlet is opposite the wall 300 or more 600 or more 600 or more  W hen front and rear side of the outdoor unit is towards the wall 300 or more 1500 or 600 or 3000 or 3000 or 200 or more...
  • Page 34: Fixing The Installation Plate

    • T he flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • T he wire assembly cable is optional. If it is not supplied, use the standard cable. • T he drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below. Optional accessories Insulated Assembly Pipe, Insulated Assembly Pipe, Insulated Assembly Pipe, Insulated PE T3 Foam Tube Vinyl Tapes (2) Ø9.52 mm (1) Ø12.70 mm (1) Ø15.88 mm (1) Assembly Pipe, Insulation (1)
  • Page 35 1. Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter of 65 mm so that it slants slightly downwards. (Unit : mm) Pipe hole Pipe hole (Ø65mm) (Ø65mm) (Ø65mm) (Unit : mm) • M ake sure to drill only one hole after choosing the Model...
  • Page 36: Connecting The Assembly Cable

    Connecting the assembly cable Cable specification Model Power cable Interconnection cable Type GL 3G x 1.0 mm², H05VV-F 5G x 1.0 mm², H07RN-F 20 A 09/12 3G x 1.5 mm², H05VV-F 5G x 1.5 mm², H07RN-F 18 25 A 3G x 2.5 mm², H07RN-F 3G x 2.5 mm², H05VV-F 24...
  • Page 37 Connecting the assembly cable  W hen you install the unit, make first refrigerant connections and then electrical connections. Connect the air conditioner to grounding system before performing the electrical connection. If unit is uninstalled, first disconnect electrical cables, then refrigerant connections. If the outdoor unit is more than 5 meters away from the indoor unit, you must extend the cable. The maximum length of the cable is 15(09/12/18) / 20(24) meters.
  • Page 38: Installing And Connecting The Assembly Pipe Of The Indoor Unit

    Installing and connecting the assembly pipe of the indoor unit Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used. There are 2 refrigerant pipes of different diameters: • The smaller one is for the liquid refrigerant • The larger one is for the gas refrigerant A short pipe is already fitted to the air conditioner. You may need to extend the pipe using the assembly pipe (optional).
  • Page 39: Evacuating The Indoor Unit

    Evacuating the indoor unit The indoor unit is supplied with inert gas (nitrogen). Before installing the unit, check if nitrogen gas flows out of indoor unit. If this one isn’t true, DO NOT INSTALL THE UNIT since leakage could be inside the indoor unit. 1.
  • Page 40: Installing And Connecting The Drain Hose Of The Indoor Unit

    Cutting or extending the pipe 5. Check if you flared the pipe correctly (see examples of incorrectly flared pipes below). Correct Damaged Uneven Inclined Cracked Surface Thickness 6. Align the pipes to connect them easily. Tighten the flare nuts first with your hands, and then with a torque wrench, applying the following torque: Torque Flare nut...
  • Page 41 Installing and connecting the drain hose of the indoor unit After completing the installation of the drain hose, pour water into the drain pan to check whether the hose is well less Ditch drained. Keep a clearance of at least Do not place the end of the 5cm between the end of the drain hose in a hollow.
  • Page 42: Changing Direction Of The Drain Hose

    Installing and connecting the drain hose of the indoor unit 6. Pass the drain hose under the refrigerant pipe, keeping the drain hose tight. Shield 7. Pass the drain hose through the hole in the wall. Check if it slants downwards as seen in the picture. 8. Using natural drainage method, check the drainage is normal. Drain hose Extension drain hose • T he hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 46 for further details.
  • Page 43: Installing And Connecting The Drain Hose Of The Outdoor Unit

    Installing and connecting the drain hose of the outdoor unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following. 1. Insert the drain plug into the drain hole on the underside of the outdoor unit. • T o avoid drain plug from contacting the ground, secure gap between the Drain plug ground and the bottom surface of the outdoor unit. Drain hole Bottom surface of outdoor unit 2.
  • Page 44 Evacuating the connected pipes Outdoor unit Indoor unit 1. Connect each assembly pipe to the appropriate valve on the outdoor unit and Gas pipe side tighten the flare nut. 2. Tighten the flare nut first with your hands, and then with a torque wrench, Liquid pipe side applying the following torque.
  • Page 45: Performing The Gas Leak Tests

    Performing the gas leak tests Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate). Test part for outdoor unit Test part for indoor unit Tightening torque for body cap...
  • Page 46: Fixing The Indoor Unit In Place

    Fixing the indoor unit in place Perform the following work on the area where gas leak test was done priory. After checking for gas leaks in the system, insulate the pipe, hose and cables. Insulation Then place the indoor unit on the installation plate. 1. To minimise condensation problems, wrap foam insulation (as shown in the figure) on a part without insulation on the end of the pipes.
  • Page 47: Smart Install Mode

    Smart Install mode This model supports Smart Install mode which checks installation status to find out if there is any problems with any of the functions . Execute Smart Install mode after installation . 1 . Check the installation status of the air conditioner . 1) Check the power supply, service valve (if it's open), power cable of the indoor and outdoor unit and amount of additional refrigerant required for pipe extension .
  • Page 48 2) Smart Install mode in progress • 88 Display : Progress will be displayed in 0~99 . • LED Display : Indicator on the indoor unit display will blink in sequence and then all indicators will blink . (This will be repeated .
  • Page 49: Final Check And Trial Operation

    Final check and trial operation To complete the installation, perform the following checks and tests to ensure that the air conditioner operates correctly. Check the followings: • Strength of the installation site • Tightness of pipe connection to detect gas leak • Electric wiring connection • Heat-resistant insulation of the pipe • Drainage • Grounding conductor connection • Correct operation (follow the steps below) 1. Press the Power button and check the following: The indicator on the indoor unit lights up.
  • Page 50: How To Connect Your Extended Power Cables

    How to connect your extended power cables Items to prepare (compressor and insulation tape should be prepared by an installation technician.) Tools Crimping pliers Connection sleeve (mm) Insulation tape Contraction tube (mm) Spec MH-14 20xØ7.0(HxOD) Width 18 mm 50xØ8.0(LxOD) Shape 1. As shown in the figure, peel off the shields from the rubber/wire (Unit: mm) of the power cable.
  • Page 51 English-51 RC_BORACAY_IB&IM_EN_DB68-05679A-00.indd 51 2/1/2016 2:20:12 PM...
  • Page 52 CALL OR VISIT US ONLINE AT 021-8255 [CE] IRAN www.samsung.com/iran/support 021-42132 [HHP] www.samsung.com/sa/home SAUDI ARABIA 800 247 3457 (800 24/7 HELP) www.samsung.com/sa_en www.samsung.com/ae/support U.A.E 800-SAMSUNG (800 - 726 7864) www.samsung.com/ae_ar/support www.samsung.com/ae/support QATAR 800-CALL (800-2255) www.samsung.com/ae_ar/support www.samsung.com/ae/support BAHRAIN 8000-GSAM (8000-4726) www.samsung.com/ae_ar/support www.samsung.com/ae/support OMAN 800-SAMSUNG (800 - 726 7864) www.samsung.com/ae_ar/support...

This manual is also suitable for:

Ar24kpfhbwkx

Table of Contents