Download Print this page

Vauconsant A62508 User Manual page 7

Exigence – air bain-marie & heat cupboard with heating display option

Advertisement

Always take care to switch off the appliance with energy doser, thermostat and switch before
cleaning. This unit is not impermeable to water. Do not use a high pressure water jet to clean it
inside or out.
Every day:
Metal surfaces:
Stainless steel should be cleaned with soapy warm water or a special product for high quality
metal surfaces. Never use abrasive sponges or etching agents to avoid scratching the surface.
glass (breath shield):
All glass displays must be cleaned using a high quality glass cleaning product and clean cloth.
Never use abrasive sponges or etching agents to avoid scratching the surface.
Symptoms
Possible causes
No electricity supply
Light off, no
heat
Cable disconnected or cut
Light on, no
heat
Defective heating element
No ventilation
Defective ventilator
No electricity supply
Light off, no
heating or
ventilation
Defective heating element
Cable disconnected or cut
Light on, no
heat
Defective safety thermostat
Ventilator blocked or
Light on, no
ventilation
Cable disconnected or cut
Halogen bulb burnt
A halogen
lamp does not
Supply of this defective
come on
No electricity supply
None of the
halogen lights
come on
Defective switch
NB
Bulbs should be replaced with bulbs of equivalent power. (see the Spare Parts section)
Fuses should be replaced by gG fuses of the same caliber.
Vauconsant SA, all rights reserved A625xx -rev0-ENG, 14/10/2010
Cleaning
Diagnostic
Burnt fuse
Faulty supply
Burnt fuse
Faulty supply
Burnt fuse
Faulty supply
defective
halogen
Burnt fuse
Faulty supply
Check the general circuit breaker
Check the fuse in the electric cabling
Check the supply cable
Check and test the electric input on the heating elements
Replace the heating element
Check and replace fuse 2A
Test and replace the ventilator
Check the ventilator's supply cable
Check the general circuit breaker
Check the fuse in the electric cabling
Check the supply cable
Replace the heating element if necessary
Check and test the electric input on the heating elements
Check and test the electric inlet on the safety thermostat.
Clean or replace the ventilator
Check and test the electric input on the ventilator
Replace the bulb with one of equivalent power
Check supply of halogen
Check the general circuit breaker
Check the fuse in the electric cabling
Check the supply cable to the heating display
Check the switch, replace it if necessary
USER MANUAL
Remedies
- 7 -

Advertisement

loading

This manual is also suitable for:

A62513A62515A62519A62522E62513tiE62515ti