OPERATING INSTRUCTIONS
6
5
4
D
C
Led Indicators
1. W.F-LED
Red
2. POWER-LED Green
3. SET-LED
Green
4. TIM-LED
Green
5. LF-LED
Green
6. HF-LED
Green, Red
Humidity Level & Timer 2 digit display
The indicator features 3 functions:
when the unit is plugged in, it will indicate the room
humidity level.
when you set the humidity, it will indicate the
humidity that you have selected
when you program the time for the unit to turn on
and off, it will show the hours.
When the environment humidity is lower than 35%,
it will show 35
When the environment humidity is higher than
95%, it will show 95
Push Button Functions
A Power Push Button
B Adjustable Humidity Push Button
C Timer Push Button
D Fan Speed Push Button
English
3
2
1
B
A
Water full-Led
Power Led
Set-Led
Timer-Led
Low-fan Led
High-fan Led
Operating Instructions
1. The Power indication light will turn on in green
when the unit is plugged in, regardless of whether
the unit is operating or not.
2. Press
, button once to start operation. Press it
again to stop operation
3. Press
button as follows: Press to set the desired
fan speed. It can be adjusted between high speed
and low speed.
4. Press
, button to set the desired humidity level in
the room, which can be set from 40% to 80% at 5%
intervals.
After a period of working,when environment humidity
is lower than the selected humidity by 2%, compressor
will stop; When environment humidity is equel to or
higher than the selected humidity by 2%, compressor
will restart once 3-minute compressor protection time
over.
5. Press
button can be timer setting:
Press the button to program the time when the unit
turns on and turns off. If you want to cancel the timer
programming, press the button to adjust the time at
00, and press the button ,it will be circulate from 00-
01-02......23-24.It is the programmed time to switch
the machine. The programmed time will be cancelled
when to switch compressor manually each time. The
programmed time remains unchanged if the machine
stops to wok due to water full or during defrosting.
DRAINING THE COLLECTED WATER
When the drainage tank is full, the tank full indicator
light will turn on, the operation will stop automatically
and the buzzer will beep 15 times to alert the user, that
the water need to be emptied from the drainage tank.
Emptying the Drainage Tank:
Lightly press on the sides of the tank with both
hands and pull the tank out gently.