Cold Weather Starting - Kubota Z482-E Operator's Manual

Hide thumbs Also See for Z482-E:
Table of Contents

Advertisement

4. Insert
the
key into
the
key switch and
turn
it
"ON".
1ABAAAAAP1250
(A)
"OFF" SWITCHED OFF
(8)
"ON" OPERATION
(C)
"GL"
PREHEATING
(D)
"ST" STARTING
5.
Turn the
starter switch
to
the
"PREHEATING" position to allow the
glow
lamp
to
redden.
6.
Turn the key
to
the
"STARTING"
position and
the
engine should start.
Release
the
key immediately when the
engine starts.
7. Check to see that the oil pressure
lamp
and charge
lamp
are off.
If
the
lamps
are still on,
immediately
stop the
engine, and determine
the
cause.
(See "CHECKS
DURING OPERATION"
in Operating
the Engine Section)
NOTE:
• If the oil pressure lamp should be still on, immediately
stop
the
engine and
check;
- if there is enough
engine oil.
-
if the engine oil has dirt in it.
- if the wiring is
faulty.
8.
Warm up
the engine at medium speed
without
load.
IMPORTANT:
If the glow lamp
should
redden too quickly or too
slowly,
immediately ask your
KUBOTA
dealer
to
check
and repair it.
If the engine does not catch or start at
10
seconds after
the starter switch is set at "STARTING ..
position,
wait
for another 30
seconds
and then begin
the
engine
starting sequence again. Do not allow the starter
motor
to run continuously
for
more
than
20
seconds.
OPERA TING
THE
ENGINE
5
COLD
WEATHER
STARTING
If
the ambient temperature is below*
-ft
C(23°
F)
and the
engine is
very cold,
start it
in the
following manner:
Take steps
(1) through
(4)
left.
5.
Turn the
key to
the
"PREHEATING"
position and keep it there for a certain
period
mentioned below.
IMPORTANT:
Shown
below are the standard preheating times for
various temperatures. This
operation,
however,
is
not
required, when
the engine is
warmed
up.
Ambient
Preheating time
temperature
Ordinary heat type
With glow lamp
timer
Above
1o·c
(50°F)
NO NEED
1o·c
(S0°F) to
Approx.
-s·c
(23°F)
5
seconds
Approx.
See NOTE:
*Below
-s·
C
(23°
F)
10
seconds
Limit
of
20
seconds
continuous use
NOTE:
In case of installing standard glow
lamp,
glow lamp
goes off after about 6
seconds,
when the starter switch
key is turned to the
"PREHEATING"
position.
However
if
necessary,
keep the starter switch key
at
the
"PREHEATING" position for longer
time,
according
to
the
left
recommendation.
6. Turn the key
to the "STARTING"
position and
the
engine should
start.
(If the engine fails to start after
10
seconds, turn off
the key for 5 to 30
seconds.
Then repeat steps
(5)
and
(6).)
IMPORTANT:
Do not allow the starter motor to run
continuously
for
more than
20
seconds.
Be
sure
to
warm up the engine, not only
in
winter.
but
also
in warmer
seasons.
An
insufficiently warmed-up
engine
can shorten its service
life.
When there is
fear
of temperature dropping below
-15°
C
(5°
F) detach the battery from the
machine,
and
keep it indoors in a safe
area,
to be reinstalled just
before the next
operation.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Z602-e0662-e0722-e0782-e0902-e

Table of Contents