Kohler 1031338 Service Kit Instructions page 2

Handle kit

Advertisement

Cleaning
Strap
Handle
Screw
Adjust the Water Temperature Limit ó Handle Installations
Turn on the water and adjust to the full hot position by turning
the handle toward the back of the faucet until it stops.
Determine the temperature using a thermometer. If the
temperature exceeds 105∞ F (41∞ C), complete the following steps.
Turn the handle until vertical.
Attach the cleaning strap over the sensor.
Remove the handle screw using the supplied 2.5 mm hex wrench.
Remove the handle and the limit stop.
Remove the limit stop from the handle splines.
Rotate and reposition the limit stop on the handle splines.
Rotating the limit stop clockwise toward the back of the faucet will
decrease the maximum temperature limit. Each spline represents
approximately 10∞ F (5∞ C) change in temperature.
Reinstall the handle vertically with the limit stop in place. Do
not secure the handle with the screw at this time.
Turn the handle to full hot and check the water temperature.
Repeat the above procedures until the desired temperature is
reached.
Secure the handle assembly with the screw.
Remove the cleaning strap and turn on the water.
Adjust the Water Temperature Limit ñ Vandal Resistant Installations
NOTE: If you install the vandal-resistant plug button, save the limit
stop and handle to adjust the water temperature at a later date.
Using the handle, adjust the water to the desired temperature.
Remove the handle screw using the supplied 2.5 mm hex wrench.
Press the vandal-resistant plug button and firmly into place.
1034576-9-B
Limit Stop
Plug Button
2
Tab Edge
Right Tab
Stop
Setscrew
© 2005 Kohler Co.