4. Raise the Upright (3). Slide the M10 Flat Washer
(94) onto the Patch Bolt (90). Secure the Upright by
tightening the Patch Bolt (90) into the Frame (1).
5. Thread the Long Extension Wire (100) through the
indicated hole in the Console Plate (101). Attach the
Console Plate to the Upright (3) with four Console
Plate Screws (39) and four M10 Split Washers (73).
Make sure that the Long Extension Wire is not
pinched between the Upright and the Console
Plate.
6. Connect the Long Extension Wire (100) to the corre-
sponding wire on the Console (97).
Next, connect the two Console Plate Wires (106) to
the two corresponding wires on the Console (97).
Note: Either Console Plate Wire can be attached to
either wire on the Console.
Next, attach the ground wire to the indicated hole in the
Console Plate (101) with an M4 x 16mm Screw (60).
7. Carefully feed all wires down through the Console
Plate (101). Attach the Console (97) to the Console
Plate with four M4 x 16mm Screws (60). Be careful
to avoid pinching the wires.
Refer to the inset drawing. Tap the Water Bottle
Holders (87) into the indicated holes in the Console
Plate (101).