Page 1
Installation and Operating Manual EMD series (Automatic electronic condensate drains) Please read the following instructions carefully before installing the product. Trouble free and safe operating of the product can only be guaranteed if recommendations and conditions stated in this manual are respected.
Page 2
Because of laws of physics, some vapor always condenses during compression of air. The EMD series drains consists of a water tank, valve assembly and electronics. The water tank should be the lowest part of the compressed air system where condensed water collects.
Page 3
EMD Installation and operating manual The timed venting mode is disabled initially since situations when this mode is needed are rare. The mode could be enabled through the service network. To service network, only types of EMD with communication electronics built in could be connected.
Page 4
EMD Installation and operating manual Components Do not disassemble Valve assembly, water level sensor and electronics! EMD 12 Water tank Sealing, O-Ring 100 x 1.5 Water level sensor Electronics Sealing, O-Ring 42 x 2.5 Strainer Insert Electronic housing Bolt M5x50 DIN 912 Screw M5x12 DIN 912 Washer 5.3 DIN 125A Screw M3x16 DIN 912...
Page 5
EMD Installation and operating manual EMD 25 Water tank Electronics Water level sensor Strainer Insert Sealing, O-Ring 42 x 2.5 Bolt M5x50 DIN 912 Electronic housing Washer 5.3 DIN 125A Washer 5.3 DIN 125A Valve connector Screw M5x12 DIN 912 Connector sealing Screw M3x16 DIN 912 Valve assembly...
Page 6
EMD Installation and operating manual EMD 75 Water tank cover Electronic housing cover Water tank Screw M3x16 DIN 912 Nut M5 DIN 934 Washer 3.2 DIN 125A Sealing, O-Ring fi 7x2,5 Sealing, O-Ring 100 x 1.5 Screw M5x16 DIN 912 3 x 0,75 cable Sealing O-Ring fi 95x2 Strainer Insert...
Page 7
EMD Installation and operating manual EMD 150 Water tank cover Electronic housing cover Water tank Screw M3x16 DIN 912 Nut M5 DIN 934 Washer 3.2 DIN 125A Sealing, O-Ring fi 7x2,5 Sealing, O-Ring 100 x 1.5 Screw M5x16 DIN 912 3 x 0,75 cable Sealing, O-Ring fi 95x2 Strainer Insert...
Page 8
EMD Installation and operating manual EMD12 Technical data Type EMD 12 230V EMD 12 115V EMD 12 24Vac EMD 12A 24Vdc 230V ac, 115V ac, 24V ac, Voltage 24V dc 50 – 60Hz 50 – 60Hz 50 – 60Hz Fuse inside EMD 5x20 1A T Power 10VA...
Page 9
EMD Installation and operating manual EMD 25 Technical data Type EMD 25 230V EMD 25 115V Voltage 230V ac, 50 – 60Hz 115V ac, 50 – 60Hz Fuse inside EMD 5x20 1A T Power 22 VA 1 – 16 bar Operating pressure range (14 –...
Page 10
EMD Installation and operating manual EMD 75 Technical data Type EMD 75 230V EMD 75 115V Voltage 230V ac, 50 – 60Hz 115V ac, 50 – 60Hz Fuse inside EMD 5x20 1A T Power 22 VA 1 – 16 bar Operating pressure range (14 –...
Page 11
EMD Installation and operating manual EMD 150 Technical data Type EMD 150 230V EMD 150 115V Voltage 230V ac, 50 – 60Hz 115V ac, 50 – 60Hz Fuse inside EMD 5x20 1A T Power 22 VA 1 – 16 bar Operating pressure range (14 –...
EMD Installation and operating manual Signal connection Version Service Network Connection Alarm output EMD 12 EMD 12A EMD 12C EMD 25 EMD 25A EMD 25C EMD 75 EMD 75A EMD 75C EMD 150 EMD 150A EMD 150C * EMD 12 24V ac only available in normal and alarm version ** EMD 12 24V dc only available in alarm version For more details about signals see chapters ‘Electrical wiring’...
Use the device for the appropriate purpose only. Appropriate use EMD series electronic condensate drains are intended exclusively for the following purpose: Draining condensate from compressed air system (air compressors, air receivers/pressure vessels, air dryers and air filters).
Page 14
Do not use tapered thread! Internal thread The EMD series could be mounted horizontally (left) or vertically (right). But, it must not be rolled aside more than ±15°. The horizontal position is preferred in case of a lot of debris in condensed water.
Page 15
EMD Installation and operating manual Horizontal drainage pipes must be inclined so that air could escape from EMD and that debris is flushed toward EMD (left). When horizontal drainge pipes are long, venting should be built (right). If if the bottom connection is used, the height of Use upper connection to mount venting line back the upper connection must be lower than the to pressure equipment (e.g.
EMD Installation and operating manual Electrical wiring: Fully disconnect power from EMD before opening the cover of electronic compartment. Please ensure that the installation is carried out according to valid regulations. 2 x 0,75mm + PE Oil resistant insulation recomended Power Connection Cable Wires should be equipped with appropriate 8 mm...
Page 17
EMD Installation and operating manual EMD series 230Vac, 115Vac EMD12 24Vac EMD12A 24Vdc EMD A series 230Vac, 115Vac EMD12A 24Vac EMD C series 230Vac, 115Vac Power Connection Power Connection Power Connection 1 230Vac (115Vac) Neutral 1 24Vac (grounded line) 1 24Vdc positive pole...
EMD Installation and operating manual Operation By pressing the test button, valve is opened. Green LED indicator shows water level in tank. Short green flashes show that water in tank is under the threshold. Test button Long green flashes indicate that the tank is almost full.
Page 19
EMD Installation and operating manual Service Network and Alarm EMD variants C, which are equipped with communication electronics and connector could be connected to a Service Network. The Service Network is a communication protocol used in EMD and other compressed air equipment that allow a remote supervision. Work data could be regularly read out of the device with a network or they could be read by a data logger.
Page 20
EMD Installation and operating manual Important Service Network command message codes and their meaning Code Description 0x80…0x9F Device data 0x84 Device Name Manufacturer, manufacturer’s address and other important data. 0xA0…0xBF Device State 0xA4 Device condition – general 0xA8 Power on counter, Elapsed hours counter 0xAC Valve operation counter, Timed venting counter 0xB0...
EMD Installation and operating manual Maintenance For EMD to work reliably, a strainer should be cleaned regularly. The Strainer of EMD is located in the entrance to a valve. Its purpose is to intercept larger solid particles that would clog valve. Cleanings period depends on condition of compressed air system. The valve is due to wear.
Page 22
EMD Installation and operating manual Replacement of valve assembly Keep to the safety rules when working with pressure equipment. First, close the valve then press the test button to depressurize EMD. Remove ø8 tube from push connection. Unscrew connector bolt an carefully remove connector and connector sealing from valve assembly.
EMD Installation and operating manual After maintenance work, press the test button to drain all condensed water which has meanwhile collected in the compressed air system. Warranty exclusion The guarantee shall be void if: The installation and operating manual was not followed with respect to installation, ...
EMD Installation and operating manual Troubleshooting After powering EMD, it enters overload mode and afterwards, it enters alarm mode. During power down, large amount of condensed water has collected in compressed air system. Hold the test button until all the water is drained. EMD enters alarm mode occasionally.