Summary of Contents for OMEGA AIR EMD12 Series

  • Page 1 Installation and Operating Manual (EMD12) 3400598- EMD12_v2.01-OmegaAir_eng...
  • Page 2 EMD12 Installation and operating manual Description EMD12 is an electronically controlled condensed water drain that discharges water trapped in the lowest parts of compressed air installation out of the system. This water is a condensed water vapor that is always present in the atmosphere. Because of laws of physics, some vapor always condenses during compression of air.
  • Page 3 EMD12 Installation and operating manual The main mode of operation is a water level triggered discharging. The valve opens when water level in EMD12’s tank reaches threshold and it closes back before the tank is empty. This way, only condensed water is discharged and no compressed air is lost. In the timed venting mode, the valve is opened when water level reaches threshold, too.
  • Page 4 EMD12 Installation and operating manual Components Remarks: Electronics Communication electronics Do not disassemble parts from 1 to 9 (Water  Electronic housing Tank, Water level sensor and Electronics). Sealing, O-Ring 42 x 2.5 Water level sensor Water tank Sealing, O-Ring 14 x 2.0 Service Network Connector Screw M3x16 DIN912 Washer 3.2 DIN125A...
  • Page 5: Technical Data

    EMD12 Installation and operating manual Technical data EMD12 EMD12A EMD12C EMD12 EMD12A EMD12C EMD12 EMD12A EMD12A Type 230V 230V 230V 115V 115V 115V 24Vac 24Vac 24Vdc Service Network Connection Alarm output Voltage 230V ac, 50 – 60Hz 115V ac, 50 – 60Hz 24V ac, 50 –...
  • Page 6: Safety Instructions

    EMD12 Installation and operating manual Safety instructions Installation and maintenance work may only be carried out when the device is  not under pressure. To depressurize the device, close ball valve and press the test button on device until pressure in it drops. Installation and maintenance work may only be carried out by trained and ...
  • Page 7 EMD12 Installation and operating manual Installation guidelines Keep to the safety rules when working with pressure equipment. The EMD12 should be connected to a pressure system by ball valve and pipe union. G 1/2" Internal thread This way, it is not needed to depressurize the whole system each time strainer cleaning or other maintenance takes place.
  • Page 8 EMD12 Installation and operating manual Horizontal drainage pipes must be inclined so that air could escape from EMD12 and that debris is flushed toward EMD12 (left). When horizontal drainge pipes are long, venting should be built (right).   Venting is made by T-piece. The T-piece should be located just infront of valve so that path from the EMD12 tank to the venting piece is as short as possible to prevent...
  • Page 9 EMD12 Installation and operating manual EMD12 230Vac, 115Vac EMD12 24Vac EMD12A 24Vdc EMD12A 230Vac, 115Vac EMD12A 24Vac EMD12C 230Vac, 115Vac 7 8 9 10 7 8 9 10 Power Connection Power Connection Power Connection 1 230Vac (115Vac) Neutral 1 24Vac (grounded line) 1 24Vdc positive pole 2 230Vac (115Vac) Line 2 24Vac...
  • Page 10 EMD12 Installation and operating manual Provide means for full disconnection of electric power from EMD12. Do not connect EMD12 after protection device of heavy inductive load like compressor motor (left). Instead, heavy inductive load and EMD12 should be protected separately (right). ...
  • Page 11: Operation

    EMD12 Installation and operating manual Operation By pressing the test button, valve is opened. Green LED indicator shows water level in tank. Short green flashes show that water in tank is under the threshold. Test button Long green flashes indicate that the tank is almost full.
  • Page 12 EMD12 Installation and operating manual Service Network and Alarm/ Warning output EMD12 variants C, which are equipped with communication electronics and connector could be connected to a Service Network. The Service Network is a communication protocol used in EMD12 and other compressed air equipment that allow a remote supervision. Work data could be regularly read out of the device with a network or they could be read by a data logger.
  • Page 13 EMD12 Installation and operating manual Important Service Network command message codes and their meaning Code Description 0x80…0x9F Device data 0x84 Device Name Manufacturer, manufacturer’s address and other important data. 0xA0…0xBF Device State 0xA4 Device condition – general 0xA8 Power on counter, Elapsed hours counter 0xAC Valve operation counter, Timed venting counter 0xB0...
  • Page 14: Maintenance

    EMD12 Installation and operating manual Maintenance For EMD12 to work reliably, a strainer should be cleaned regularly. The Strainer of EMD12 is located in the entrance to a valve. Its purpose is to intercept larger solid particles that would clog valve. Cleanings period depends on condition of compressed air system. The valve is due to wear.
  • Page 15: Troubleshooting

    EMD12 Installation and operating manual 7. Connect hose to outlet “push” connection, connect power supply and slowly pressurize the unit. 8. Check for any potential leakages and press test button to check proper operation. After maintenance work, press the test button to drain all condensed water which has meanwhile collected in the compressed air system.
  • Page 16: Warranty Exclusion

     Unauthorized constructional changes were made to the unit or if the unit has  been opened/disassembled by an unauthorized person. OMEGA AIR d.o.o. Ljubljana Cesta Dolomitskega odreda 10 SI-1000 Ljubljana, Slovenia Tel.: +386 (0)1 200 68 00 Fax.: +386 (0)1 200 68 50 E-mail: info@omega-air.si...