Common Faults And Treatment - Siruba C007KD Manual

Electronic control parameter
Hide thumbs Also See for C007KD:

Advertisement

顯示速控器電壓
P-39
display the volt of
speed controller
顯示直流母線電壓
P-40
display DC buses
voltage
過壓保護開關
P-41
overload protection
switch
四、一般故障處理:
錯誤內容
錯誤碼
Error content
Error code
找不到停針位
Er01
Can't find the
needle position
開機沒有檢測
到調速器
Er02
Not detected
boot speed
regulator
電機霍爾或相
位線錯誤
Er03
Motor holzer or
phase error
14-1010
60-500V
0:關閉 1:開啟
0: close 1:start
Common faults and treatments
Several possible error problem
1.手輪靠的不夠近間隙在 2.5mm 內
2.九針插頭接觸不良
3.電機霍爾壞,要更換電機
4.手輪上的磁鐵掉落
1. The hand wheel is not close, clearance within 2.5 mm
2. Nine plug contact undesirable
3. Motor holzer bad, to replace the motor
4. The hand wheel magnet in the loss
1.調速器插頭沒有插
2.調速器線斷了或接觸不良
1. Speed control device without plug
2. Speed wire is broken or contact undesirable
1.九針插頭接觸不良
2.電機沒有安裝好,參照圖 A
3.霍爾壞
1. Nine hole plug contact undesirable
2. The motor doesn't pack good
3. Holzer is bad
顯示當前速控器電壓 0—
中點電壓
195
Display the current speed
Neutral
controller volt 0-1024, it is
point volt
當電壓高於 395 會報警,
(直流母線電壓/1.414=交
流母線電壓)when the volt
320v
alarm,(DC buses volt/1.414
設為 0 關閉過壓報警,設
為 1 打開報警,當直流母
線電壓超過 395V 時,報
警 Er16,電機自動停止運
385v 電機可再次運行 set
1
alarm, when DC buses voltage is
over 395 V , will display Er16,
the motor will stop automatic,
錯誤問題的多種可能
1024,相當於 0-5V
equal 0-5V
is higher than 395V will
= AC buses volt )
行,報警後當電壓低於
"0" is close the overload
alarm, set "1" is open the
when volt is lower 385V, the
motor can run.

Hide quick links:

Advertisement

loading

This manual is also suitable for:

S007kd