INDEX TECHNICAL DATA TECHNICAL DATA PRE-INSTALLATION INFO PACK CONTENTS 6-10 INSTALLATION FILLING THE SOAP TANK EXTREME CS SD B 237891 EXTREME CS SD 2030B 237896 EXTREME CS SD E EXTREME CS SD 2030E 237890 237892 REMOTE CONTROL FUNCTIONS BATTERY REPLACEMENT...
Stern liquid soap dispensers are suitable for use with any generic liquid soap of the correct viscosity and pH. The pH level of all soap used in Stern liquid soap dispensers should be between 6.5 to 8.5. Lower levels will cause corrosion to the metal dispenser...
Page 4
PACk CONTENTS PACk CONTENTS EXTREME CS SD 2030B / E MF EXTREME CS SD E 1 x Body assembly 1 x Body assembly 1 x Wall Rosette 1 x Elbow and Corrugated Tube 1 X quick connection fitting 12V Transformer B VERSIONS E VERSIONS 1 x pump assembly...
INSTALLATION INSTALLATION EXTREME CS SD B / E EXTREME CS SD B / E STEP 1 – PREPARATION FOR INSTALLATION Connect the soap tube that is coming out of the soap dispenser 18-20 mm body to the quick connector at the...
Page 6
INSTALLATION INSTALLATION EXTREME CS SD B / E EXTREME CS SD 2030B / E IMPORTANT: the 4 contacts connector should be connected properly so that the white STEP 1 – INSTALLINg THE EXTREME CS SD 2030B / E o-ring is not visible and a clicking sound is heard.
INSTALLATION FILLINg THE SOAP TANk EXTREME CS SD 2030B / E If your model is an MF model, please refer to the Multifeed installation guide. STEP 3 – CONNECTINg THE POWER SOURCE Unscrew the soap tank from the pump assembly and Remove the protective sticker pull it out from the bottle support.
BATTERY REPLACEMENT REMOTE CONTROL FUNCTIONS If you acquired the remote control together with your soap dispenser, you may adjust Battery models only the dispenser settings if required. To use the remote control hold it straight in front of When the battery weakens, the red indicator light will blink at a constant rate when the the sensor at a distance of about 10-15 cm (4-6”).
6-Pack Soap Bottle 1L 07100035 If a defect is found in normal use, Y. Stern Engineering Ltd. will, at its discretion, repair, provide a replacement part or product, or make appropriate adjustments. Damage caused 6-Pack Soap Bottle 1L Support Kit 07100037 by accident, misuse, or abuse is not covered by this warranty.
TROUBLESHOOTINg TROUBLESHOOTINg Indication Investigation Cause Solution Illustration Indication Investigation Cause Solution Illustration False Continuous AUX connector not The connector should be inserted fully until Soap not Pump is Sensor is AUX connector not The connector should be inserted fully activation: discharge from the fully inserted white o-ring is not visible.