System Parameters Setting List; Parameter Mode; Composite Keys That - Jack k4 Series Manual Book & Parts Book

Hide thumbs Also See for k4 Series:
Table of Contents

Advertisement

2.3 Composite keys that

3 System parameters setting list

3.1 Parameter mode

1 In the standby state ,press
2 Press corresponding key
When the parameter values have increased and decreased, parameter interface flash. Short press
parameters .Long press
NO.
Range
P 9 9
0~2
P 0 1
200~5000
P 0 3
0/1
P 0 4
200~3000
P 0 5
200~3000
P 0 7
0~200
P 0 8
0~200
P 0 9
0/1
P 1 0
0~4
P 1 6
1~3000
+
+
key to enter the parameter modes.
and key
key to exit parameter interface, return to standby model.
Default
1
language selection 0: off, 1: Chinese, 2:English, default language 1 Chinese
4000
the maximum speed of free sewing (the global maximum speed)
0
Needle stop position selection (0:up; 1: down)
1800
Start encryption sewing speed
1800
End encryption sewing speed
Start encryption stitches number (0 is not encrypted function, if there is a pin number for
0
encryption seam features)
0
End encryption stitches number (0 is not encrypted function, if there is a pin number for
encryption seam features)
0
Soft start switch (0:off; 1: on)
0
Quantity of meter to adjust
50
Adjust the lift foot response time after the sensor has detected the cloth.
to adjust the corresponding parameter.
Description
4/8
key to save the modified