9c
Connect the cam to the indicator slide. The cam must
engage either the left or right side of the indicator slide
according to door handing and indicator location.
• Unlock the door.
• Move the indicator slide against the top rim of the
mounting plate (unlocked position).
• Assemble the cam as shown.
Door Hand/Indicator Location
Lock Type
Non-deadbolt
RH/Outside
functions
LH/Inside
Deadbolt
RH/Inside
functions
LH/Outside
9d
Place the escutcheon faceplate on the indicator
assembly.
Cylinder and thumb turn applications are shown below.
Escutcheon
faceplate
L Thumb turn must be in
vertical position when
indicator slide is in up
(unlocked) position.
Thumb turn
Escutcheon
faceplate
10
RH/Inside
LH/Outside
RH/Outside
LH/Inside
Indicator slide in
unlocked position
Indicator trims are shown above. Depending on the lock configuration,
the inside trim may not have an indicator.
Indicator slide in
unlocked position
Install inside trim