Injector table

Injector table
Category II2H3B/P (AT) - II2ELL3B/P (DE)
Type of gas used Type of
NATURAL GAS
(Methane)
G20
NATURAL GAS
(Methane)
G25*
LIQUEFIED
PETROLEUM GAS
(Butane) G30
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Type of gas
used
G20 20 mbar
G25* 20 mbar
G30 50 mbar
G31 50 mbar
* NOT FORESEEN FOR AUSTRIA
Electric Power: 220-240 V ~ 50-60 Hz - 1,1 W
Injector
burner
marking
rapid
128 B
semi-rapid
104 B
semi-rapid
104 B
auxiliary
78 A
rapid
135
semi-rapid
1 15
semi-rapid
1 15
auxiliary
82
rapid
78 D
semi-rapid
62 B
semi-rapid
62 B
auxiliary
46
rapid
78 D
semi-rapid
62 B
semi-rapid
62 B
auxiliary
46
Model
Nominal heating
capacity kW
1R - 2 SR (2kW) -
1 AUX
1R - 2 SR (2kW) -
1 AUX
1R - 2 SR (2kW) -
1 AUX
1R - 2 SR (2kW) -
1 AUX
Nominal
Nominal
heating
consum-
capacity
ption
kW
3,00
286 l/h
2,00
190 l/h
2,00
190 l/h
1,00
95 l/h
3,00
332 l/h
2,00
221 l/h
2,00
221 l/h
1,00
1 1 1 l/h
3,00
218 g/h
2,00
145 g/h
2,00
145 g/h
1,00
73 g/h
3,00
214 g/h
2,00
143 g/h
2,00
143 g/h
1,00
71 g/h
Total nominal
consumption
8,00
761 l/h
8,00
885 g/h
8,00
581 g/h
8,00
571 g/h
Reduced
Gas pressure
heat
(mbar)
capacity
kW
min. nom. max.
0,70
0,40
17
20
0,40
0,40
0,70
0,40
18
20
0,40
0,40
0,80
0,50
42,5 50
0,50
0,45
0,80
0,50
42,5 50
0,50
0,45
Air necessary
(m
) for
3
combustion
1 m
of gas
3
9,52
8,187
30,94
30,94
14
10
25
25
57,5
57,5