Everbilt SBF300 Use And Care Manual

Everbilt SBF300 Use And Care Manual

Submersible effluent pump
Table of Contents

Advertisement

Available languages

Available languages

SKU # 1002 246 716
Model # SBF300
USE AND CARE GUIDE
SUBMERSIBLE EFFLUENT PUMP
Questions, problems, missing parts? Before returning to the store call
Everbilt Customer Service
8 a.m. - 6 p.m., EST, Monday-Friday
1-844-241-5521
HOMEDEPOT.COM
THANK YOU
We appreciate the trust and confidence you have placed in Everbilt through the purchase of this submersible effluent pump. We strive to continually
create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
Thank you for choosing Everbilt!

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Everbilt SBF300

  • Page 1 THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this submersible effluent pump. We strive to continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home improvement needs.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ............2 Installation ..............5 Performance ..............2 Operation ............... 7 Safety Information ............2 Care and Cleaning ............7 Warranty ................. 3 Troubleshooting ............8 Pre-Installation .............. 4 Performance GPH/GPM of Water @ Total Feet Of Lift Max.
  • Page 3: Safety Information

    Safety Information (continued) CAUTION: Know the pump and its applications, IMPORTANT: Ensure the electrical power source is limitations, and potential hazards. adequate for the requirements of the pump. CAUTION: Secure the pump to a solid base. This will aid IMPORTANT: This pump is made of high-strength, in keeping the pump in a vertical orientation.
  • Page 4: Pre-Installation

    Pre-Installation APPLICATION This unit is a submersible effluent pump and designed for pumping effluent, wastewater or flooded water with up to 3/4 in. solids. The pump is built with overload thermal protections and auto reset. The pump is equipped with a 25 ft. 3-prong grounding-type power cord and tethered float switch.
  • Page 5: Installation

    Installation TYPICAL DEWATERING INSTALLATION (3/4 in. or less Solids) NOTICE: Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or gravel surfaces. 1. Piping must be 1-1/2 in. minimum to carry volume of pump discharge. Check local codes to determine if a check valve is required in your system.
  • Page 6 Installation (continued) 13. Septic tank risers must be used for easy pump and filter access. NOTE: Double seal pumps offer extra protection from damage caused by seal failure. All installations must comply with all applicable electrical and plumbing codes, including, but not limited to, National Electrical Code, local, regional, and/or state plumbing codes, etc.
  • Page 7: Operation

    Operation WARNING: Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water, unless you are certain all power has been turned off to the pump. Remember, the pump should be connected only to a properly grounded, GFCI outlet. 1.
  • Page 8: Troubleshooting

    Troubleshooting Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may cause an oil leak or dangerous electrical wiring issues. DO NOT lift up the pump by the power cord. Problem Solution The pump fails to operate. 1.
  • Page 10 Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.COM...
  • Page 11 ¡GRACIAS! Nosotros agradecemos la confianza que Usted ha puesto en Everbilt por la compra de bomba efluente sumergible. Nos esforzamos continuamente para crear productos de calidad diseñados para mejorar su hogar. Visítenos en nuestra página de internet para ver la...
  • Page 12 Table Des matières Table Des matières ............2 Instalación ..............5 Funcionamiento ............. 2 Funcionamiento ............7 Información De Seguridad ........... 2 Cuidado Y Mantenimiento ........... 8 Garantía ................3 Solución de Problemas ..........8 Pre-Montaje ..............4 Funcionamiento GPH (Galones por hora) de Agua @ Pies (Metros) de Altura Max.
  • Page 13: Información De Seguridad

    Información De Seguridad (seguido) CAUTELA: Conozca de la bomba las aplicaciones, las IMPORTANTE: Asegure que la fuente de electricidad es limitaciones y los peligros potenciales. adecuada para los requisitos que exige la bomba. CAUTELA: Asegúrese de que la bomba esté en una IMPORTANTE: Esta bomba está...
  • Page 14: Pre-Montaje

    Pre-Montaje Aplicación Esta bomba es la bomba sumergible de efluentes y diseñado para el bombeo, efluentes, aguas residuales o agua inundada con hasta 3/4 pulgadas sólidos. La bomba está construido con protección térmica de sobrecarga y reposición automática. La bomba está equipada con un cable de 25’...
  • Page 15: Instalación

    Pre-Montaje (seguido) Especificaciones Voltaje 115V, 60 HZ., Circuito de 15 Amperios Rango de Temperatura de Líquido 0°C a 55°C (32°F a 131°F) Tamaño de descarga NPT Hembra de 2 pg. Colector de fango Minimo 18 pg. (460 mm) de diámetro 30 pg. (760 mm) a fondo Interruptor de encendido/apagado Encendido: 13.3 pg.(338 mm), Apagado: 5 pg.(127 mm) AVISO: Lea este manual de instrucciones para la instalación, operación y seguridad.
  • Page 16 Instalación (seguido) INSTALACIÓN TÍPICA PARA EFLUENTES El cableado y la protección eléctrica deben estar de acuerdo con el CódigoEléctrico Nacional y todos los otros requisitos eléctricos locales y estatalesaplicables. Instale el “Unicheck” (combinación de unión y válvula de retención) apropiado, luego arriba del estanque para que se pueda quitar fácilmente la bombapara su limpieza o reparación.
  • Page 17: Funcionamiento

    Instalación (seguido) Eléctrica ADVERTENCIA: Riesgo de choque eléctrico. Puede provocar choque, quemadura o muerte.Al instalar, operar o prestar servicios a esta bomba, respete las instrucciones de seguridad enumeradas a continuación: NO utilice cable con empalmes para la alimentación eléctrica. NO permita que el enchufe del cordón electric quede sumergido. NO use cables de prolongación.
  • Page 18: Cuidado Y Mantenimiento

    Cuidado Y Mantenimiento CAUTELA: Riesgo de descarga eléctrica. Puede lastimar, quemar o matar. No levante la bomba por el cable de alimentación. Antes de retirar la bomba de cuenca para el servicio, Siempre desconecte la  alimentación eléctrica a la bomba y el interruptor de control Sumergir la bomba en una solución desinfectante (blanqueador) durante al ...
  • Page 20 ?Preguntas, problemas, piezas que faltan? Antes de devolverla a la tienda, llame a Servicio al Cliente de 8:00 AM a 6:00 pm EST de Lunes a Viernes. 1-844-241-5521 HOMEDEPOT.COM...

This manual is also suitable for:

1002 246 716

Table of Contents