TROUBLESHOOTING

During Set House ID, the LED is not flashing on some wireless
LightSense™ devices.
If LED is solid green before initiating House ID binding:
The device already has another House ID. Reset it to the factory default
so that it can be bound to the desired House ID. Resetting to factory
defaults is described in the "I need to start over" issue.
If LED is solid yellow after initiating House ID binding:
The device may be out of range of the initiating device. Add a PSWO
LightSense Wireless Repeater to boost signal range.
During Binding, all LEDs stop flashing before I am finished.
The binding process timer may have expired. Restart the binding process
timer by repeating steps 1 and 2 of the procedure you were using. Notice
that the devices you previously included are flashing yellow; simply finish the
process from where you left off.
The device LED flashes red when I press
If house or room scene controllers are used in the house, the house or room
configuration may be locked. Consult the installation instructions for the
PSWCH or PSWRH wireless house scene controller if one is present. See
the PSWCR or PSWRR wireless room scene controller instructions if one is
present.
I made a configuration mistake. I need to start over.
You can reset any LightSense wireless device to factory default settings by
pressing and holding
(approximately 10 seconds). During the process, the LED flashes yellow and
when complete, it changes to solid yellow. The device can then be
reconfigured, exactly like any new device (see the Set House ID section).
The fan control does not work and the status LED is flashing red
at 2Hz (10 times in 5 seconds):
The fan control has detected an overload condition and has shut down.
To clear the fault condition, tap
Disconnect loads in excess of rated load and try again.
at 3Hz (15 times in 5 seconds):
The fan control has detected a short-circuit condition and has shut down.
To clear the fault condition, tap
Remove power, rectify the short-circuit, restore power, and try again.
The status LED is off.
Check the paddle position. If the bottom edge is recessed, the Air Gap
safety feature is engaged. See Fan Maintenance.
CLEANING
Clean using a cloth dampened only with water and a little mild detergent. Use
of solvents or hydrocarbon-based cleaners may cause permanent damage.
until the LED changes to solid yellow
and wait for the LED to turn green.
and wait for the LED to turn green.
.