OPERATION

Before use, set the fan to run in the appropriate direction and at full speed:
1. Press the top speed button on the PSWCF wireless fan control, and wait to
allow the fan motor to run up to full speed.
2. Using the controls on the fan (typically pull-chains), adjust so that the fan is
running at full speed, and in the desired direction. The pull chains may now
be removed or shortened.
Button and Paddle Functions
The PSWCF wireless fan control has a rocker paddle
and five speed control buttons. Use the speed buttons
to select an appropriate fan speed or OFF.
Rocker paddle functions are described below.
Tap once
Tap twice
– Press and hold
Tap once
– Press and hold
The wireless fan control may feel warm to the touch during normal operation.

Fan Maintenance

When fan maintenance is required, use the Air Gap Isolation feature for safety.
To activate the feature:
Press
FIRMLY, so that the paddle clicks and latches in. Make sure the
status LED is extinguished, indicating that the load is isolated.
To release and return to normal operation, press
Power Fail Memory
After a power failure, all LightSense™ devices automatically return to the state
they were in immediately prior to loss of power.
When you see
touch the
top of the
paddle as
directed.
Turn fan ON and resume the last used speed
Full speed
Increase the speed
Turn fan OFF
Decrease the speed
When you see
touch the
bottom of the
paddle as
directed.
.