Installation - pass & seymour legrand LightSense PSWCF Installation Instructions Manual

Wireless fan control
Table of Contents

Advertisement

TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE

INSTALLATION

For ease of installation, Pass & Seymour/Legrand recommends use of a deep
wall box.
1. Disconnect power to circuit by turning circuit breaker OFF before installation.
2. Remove existing wall plate and switch.
3. Strip existing wires
4. Connect the supply and load ground wires to the GND terminal on the back
of the unit.
5. Connect the white (Neutral) fan control wire to the white supply and white
load wires, using a wire nut.
6. Connect the black fan control wire to the black supply Line, using a wire nut.
7. Connect the red fan control wire to the black load wire, using a wire nut.
8. Attach the wall plate.
9. Switch the circuit breaker back ON.
Wire Legend
Load (red)
Ground
Neutral (wht)
Line (blk)
Visit our website for FAQs: www.passandseymour.com
CAUTION
INSTALLING THE FAN CONTROL.
1 /
.
2 "
Load
Wires
NEUT
Supply
Wires
LOAD
LINE
GND

Advertisement