Honeywell Limitless WLS Series Quick Start Manual page 4

Single switch adapter
Table of Contents

Advertisement

Limitless™ WLS Series
Single Switch Adapter
Special code BT3 or BT4 in the WLS Single Switch Adapter part number: End-user supplied three-wire electrical cable
routed through a cable grip on the WLS Single Switch Adapter and connected to an internal electrical connector.
The user supplied electrical cable must have the following characteristics:
• Cable diameter: 2,5 mm to 8,0 mm [0.10 in to 0.32 in]
• Cable length: 3 m [9.84 ft] max.
• Wire gauge: 18 AWG to 26 AWG
• Wire strip length: 5,0 mm [0.197 in]
Step
Action
1
Remove the four (4) mounting screws and the WLS Single Switch Adapter plastic head and route the user-supplied cable
through the WLS-SS cable grip. Do not tighten the cable grip at this time. See Figure 3 (page 4).
2
Connect the three (3) user-supplied wires to the user-supplied switch terminal (common, normally open, and normally
closed). See example in Figure 4 (page 5).
3
Connect the user-supplied switch (common, normally open, and normally closed) wires to the same labeled internal con-
nector (COM, NO, NC) of the WLS Single Switch Adapter. See example in Figure 5 (page 5).
4
Re-install WLS Single Switch Adapter plastic head as the cable is gently pulled through the cable grip so an excess
amount of cable is not inside the WLS Single Switch Adapter plastic head. Torque the four (4) mounting screws on the WLS
Single Switch Adapter plastic head to 1,36 N-m to 1,8 N-m [12 in-lb to 16 in-lb]. See Figure 3 (page 4).
5
Tighten cable grip nut to secure cable. See Figure 3 (page 4).
Figure 3. WLS Single Switch Adapter BT3 & BT4 Plastic Head Screws, Cable Grip, and User-supplied Cable
4
Honeywell Sensing and Control
50081314
ISSUE 1