Advertisement

82529
Issue 2
SUPER FERRONA 16 MKII
USERS
INSTALLATION
(Pages 2-3)/
(Pages 4-6)
AND SERVICING INSTRUCTIONS
THIS CAT I
APPLIANCE IS FOR USE
2H
ON NATURAL GAS G20 AT A SUPPLY
PRESSURE OF 20mbar IN GB and IE
HAND THESE INSTRUCTIONS TO THE USER

Advertisement

Table of Contents
loading

Summary of Contents for Royal Cozyfires SUPER FERRONA 16 MKII

  • Page 1 82529 Issue 2 SUPER FERRONA 16 MKII USERS INSTALLATION (Pages 2-3)/ (Pages 4-6) AND SERVICING INSTRUCTIONS THIS CAT I APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER...
  • Page 2: Important Notes

    DESCRIPTION The Super Ferrona 16 MKII is a decorative gas fire designed to fit into a conventional fire surround and fireplace. It should be fitted to a flue that conforms to a conventional Class I flue (i.e. a brick built chimney of 227 x 227mm (9x9ins) or 175mm (7ins) diameter lined or stone chimney with the fire back and fireplace components complying to BS1251.
  • Page 3 TO LIGHT THE APPLIANCE 1. Remove the fret (controls cover). 2. Press and turn the gas control until the indicator mark is opposite to IGN. Keep the control fully depressed. Press and release the ignition button. Check that the pilot flame has lit at all ports. Keep the gas control depressed for a further 20 seconds.
  • Page 4: Technical Data

    Page 3 THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS The relevant Codes of Practice and British Standards are: - BS 5440 Part 1 1990 The Building Regulations issued BS 5440 Part 2 1989 by the Department of the Environment. BS 6461 Part 1 1984 BS 5871...
  • Page 5: Connecting The Gas Supply

    Page 4 Site the appliance as far back as possible whilst maintaining a central position in the opening, establish where the fixing holes are to be. A bracket is supplied in the fixing kit; this can be located either to the front or to the rear of the fascia panel.
  • Page 6 TO LIGHT THE APPLIANCE AND CHECK THE CORRECT OPERATION 1. Remove the fret (controls cover). 2. Press and turn the gas control until the indicator mark is opposite to IGN. Keep the control fully depressed. 3. After a suitable interval to ensure that the pipes are purged of air, press and release the ignition button. Check that the pilot flame has lit at all ports.
  • Page 7: Maintenance And Servicing

    Page 6 MAINTENANCE AND SERVICING GENERAL REMOVAL OF DEBRIS or SOOT DEPOSIT Allow the appliance to cool for two to three hours before removing all of the coals and ceramic blocks for cleaning purposes. Once all the ceramics are removed from the fire bed check that no debris is located in the burner slots (both front &...
  • Page 8: Short Parts List

    Page 7 SHORT PARTS LIST For spares contact the manufacturer at the address overleaf. DESCRIPTION CROSSLEE No GC No Piezo Igniter 40245 397 686 Control Knob 40232 170 014 Control Valve 41833 386 147 Oxy-Pilot Burner Assembly (SIT) 42313 Main Injector Bray Cat 82/460 41669 379 871 (Stereomatic)
  • Page 9 Page 8...
  • Page 10 Page 9...
  • Page 11 Page 10...
  • Page 12 Page 11...
  • Page 13 MAX HEAT INPUT (GROSS) 6.6 kW 22450 Btu/hr Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX Spares Tel 01422 203963 Fax: 01422 204475 Service (GSA Ltd) 01703 516611 Customer Service 01422 200660...