Royal Cozyfires U19019 G20 User Instructions

Royal cheltenham, this cat i2h appliance is for use on natural gas g20 at a supply pressure of 20 mbar gb and ie

Advertisement

Quick Links

81139
Issue 3
USERS INSTRUCTIONS
THIS CAT I
APPLIANCE IS FOR USE
2H
ON NATURAL GAS G20 AT A SUPPLY
PRESSURE OF 20 mbar GB and IE
HAND THESE INSTRUCTIONS TO THE USER

Advertisement

Table of Contents
loading

Summary of Contents for Royal Cozyfires U19019 G20

  • Page 1 81139 Issue 3 USERS INSTRUCTIONS THIS CAT I APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar GB and IE HAND THESE INSTRUCTIONS TO THE USER...
  • Page 2: Important Notes

    DESCRIPTION The Royal Cheltenham glass fronted high efficiency live fuel effect inset gas fire has been developed from the successful Royal Cozyfires LFE using much of the technology and components used in the manufacture of this appliance. The fuel bed has a realistic coal effect utilizing ceramic ‘coals’ and coal bed that allows secondary air to be entrained into the bed for clean combustion.
  • Page 3: Technical Data

    TECHNICAL DATA Heats Input Rates: High Setting 5.42 kW Low Setting This fire will run for 5.4 hours on one therm of gas on high setting. LOCATION OF COMBUSTIBLE SHELVES ABOVE FIRE Min. Height of 150mm deep shelf above hearth = 830mm When the shelf depth is increased by increments of 12.5mm, add 25mm to the height above fire.
  • Page 4 DISMANTLING THE FIRE BED FOR CLEANING (see fig.3, 4 & 5) Allow the appliance to cool for 1 hour before handling any components. Remove the controls cover and unscrew the two wing screws securing the canopy in place as shown in (fig 3). Lift the canopy off the appliance and place to one side.
  • Page 5 COAL LAYING INSTRUCTIONS Lay the four front coals diagonally with the stepped corner sitting on the simulated coal front and the small corner notch at the rear. Lay a further row of four coals behind the front row with stepped corners in the rear corners of the front row, the two centre coals having notches in the rear top corners.
  • Page 6: Spares And Service

    For spares and service, apply to your local Supplier, Installer or direct to the manufacturer, stating that the appliance is a Royal Cheltenhan. Quote the GC Appliance Number and the Serial Number from the Data Badge located on the front control panel.
  • Page 7 __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ MAX HEAT INPUT 5.42kW 18500 Btu/h (Gross) Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX Spares Tel 01422 203963 Fax: 01422 204475 Service (GSA Ltd.) 01703 516611...
  • Page 8 81140 Issue 3 INSTALLATION AND SERVICING INSTRUCTIONS THIS CAT I APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar GB and IE HAND THESE INSTRUCTIONS TO THE USER...
  • Page 9 DESCRIPTION The Royal Cheltenham glass fronted high efficiency live fuel effect inset gas fire has been developed from the successful Royal Cozyfires. The fuel bed has a realistic coal effect utilising ceramic ‘coals’ and coal bed that allows secondary air to be entrained into the bed for clean combustion, the burner is an aerated twin ported steel burner running parallel across the front of the fire.
  • Page 10: Installation Regulations And Requirements

    INSTALLATION REGULATIONS AND REQUIREMENTS In the interests of both the Law and of Safety, this appliance must only be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and the manufacturer’s instructions.
  • Page 11 Clearance to side (timber surrounds etc.) Minimum clearance required to any combustible material to the side of the appliance must be 150mm. Clearance to shelves. Minimum clearances to undersides of a 150mm deep combustible shelf from the hearth must be 830mm.
  • Page 12 Page 5...
  • Page 13 INSTALLATION USING A 5" DIAMETER METAL FLUE BOX Important: The Flue restrictor plate must be removed see Fig 10. When the metal flue box is to be built-in as a false chimneybreast using timber stud work with plasterboard facing, the flue box should be enveloped with insulation material such as rockwool or similar to prevent a build up of heat within the structure.
  • Page 14: Installation Of The Appliance

    INSTALLATION OF THE APPLIANCE Check that the chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work, if the flue has been used for solid fuel it should be swept and a smoke test carried out to check that satisfactory smoke clearance has been established.
  • Page 15: Coal Lay-Out

    Page 7 a (ii) If the spacer frame is to be used, attach the frame to the rear of the appliance using either the screws and captive nuts removed from the appliance or supplied in the fixing kit, see fig 8. Place the fire in the required position; mark around the perimeter of the spacer frame remove the appliance and the spacer frame from the appliance.
  • Page 16 Page 8...
  • Page 17 Page 9...
  • Page 18 Page 10...
  • Page 19 Page 11...
  • Page 20 Page 12...
  • Page 21: Checking Operation Of Fire

    CHECKING OPERATION OF FIRE Purge the air from the appliance by rotating the control to the ignition position, push the control to allow the air in the pipework to be purged, push the piezo to ignite the Oxy/pilot. Check that the electrode is sparking between the tip of the thermocouple and continue until a pilot flame has been established.
  • Page 22 Complete the registration section at the end of this booklet. Advise that any component part of this appliance be guaranteed against defective workmanship or faulty materials for a period of twelve months from the date of purchase. Any such part will be replaced free of charge on receipt of the purchaser’s address at the cost of postage only, provided that: a.
  • Page 23 Page 15...
  • Page 24 ……………………………... ……………………... ……………………... Serial Number MAX HEAT INPUT 5.42kW 18500 Btu/h (Gross) Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX Spares Tel 01422 203963 Fax: 01422 204475 Service (GSA Ltd.) 01703 516611...