  • Page 1 0102 095 50261 USERS INSTRUCTIONS THIS CAT I APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB & IE HAND THESE INSTRUCTIONS TO THE USER DESCRIPTION...
  • Page 2 This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required. This appliance is intended for decorative purposes, the coal bed uses ceramic simulated coals to give a realistic appearance and to allow secondary air to be entrained into the bed to ensure clean combustion.
  • Page 3 One type of fire front and fret suggested is shown in Fig 1, this has a perforated fret to allow air to be drawn into the coal bed for combustion and over the controls for cooling purposes. If other fronts and frets are to be used they must have a minimum open area in the fret of 20 sq.
  • Page 4 It is very important that the coals and the coal bed components are laid as shown no extra coals or material may be used. If any of the items become lost or damaged, replacements must be obtained before further use of the appliance.
  • Page 5 Page 4 Page 5...
  • Page 6 Serial Number __________________________________________________ Please return this section with any components that are faulty under guarantee. MAXIMUM HEAT INPUT 6 kW - 20470 Btu/h (Gross) Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX...
  • Page 7: Installation And Servicing Instructions

    0102 095 50251 INSTALLATION and SERVICING INSTRUCTIONS THIS CAT I APPLIANCE IS FOR USE ON PROPANE GAS G31 AT A SUPPLY PRESSURE OF 37 mbar IN GB & IE HAND THESE INSTRUCTIONS TO THE USER...
  • Page 8 DESCRIPTION This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be installed into applications where the warmth and comfort of an open fire and high radiant heat is required.
  • Page 9 Installation Regulation and Requirements The appliance must be installed by a competent person in accordance with the current Gas Safety (Installation and Use) Regulations 1994 (as amended) or the rules in force and in accordance with the manufacturers instructions, failure to do so could lead to prosecution. The following are the relevant Codes of Practice and British Standards.
  • Page 10 Fire Surround and Opening Requirements Check that the chimney and flue structure are sound and conform to the following flue requirements: a) A conventional brick or stone chimney with a minimum effective cross sectional dimension of 225x225mm. A lined flue with a minimum diameter of 175mm having a chairbrick and throat forming lintel conforming to BS 1251 or a builders opening measuring 560mm high x 400mm wide with a depth of 185mm minimum for debris collection.
  • Page 11 Installation of the Appliance Check that the chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work as necessary, if the flue has been used for solid fuel it should be swept and a smoke test carried out to check that satisfactory smoke clearance has been established.
  • Page 12 Installing the Appliance in Position When the gas supply pipe has been laid to the position required, the surround should be fitted and sealed to the chimney correctly. This is to prevent any seepage of flue products or to prevent any ingress of air into the flue from anywhere other than the flue outlet of the fire.
  • Page 13 To check the gas pressure at the appliance, allow the coals and the coal bed to cool and turn off the gas supply at the isolating cock. Remove the hexagon headed screw and connect a manometer to the pressure test point, turn on the gas and ignite the fire, allow to heat up and check that the gas pressure is 37 mbar +/- 1 mbar - any appreciable drop may indicate restrictions through the pipework up to the fire.
  • Page 14 Maintenance and Servicing GENERAL REMOVAL OF DEBRIS OR SOOT DEPOSITS Allow the appliance to cool sufficiently before removing all of the coals and firebed components for cleaning purposes. Once all the ceramics are removed from the firebed check that no debris is located in the burner slots (both front and rear).
  • Page 15 Page 9...
  • Page 16 Page 10...
  • Page 17 Page 11...
  • Page 19 Page 12...
  • Page 20 Page 13...
  • Page 21 No Figures 13 & 15 On this page Page 14...
  • Page 22 Date of Purchase ... Serial No ... Please return this section with any components that fail under guarantee. Maximum Heat Input 6 kW 20470 Btu/h (Gross) Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX...