Electrical Connections - Empire Comfort Systems VFLB36FP30N Installation Instructions Manual

Heat management systems kit

Advertisement

BAND CLAMP
BAND CLAMP
6"
DIAMETER
FLEX
DUCT
6" DIA
FLEX DUCT
AND INSULATION MATERIALS FROM FLEX VENTING
NOTE: FLEX VENTING MUST BE SUPPORTED WITH
WIRE OR PLUMBERS STRAPPING AT INTERVALS THAT
NOTE: Flex venting must be supported with wire or plumbers
ADEQUATELY SUPPORT THE VENT PIPE. 2'-3' INTERVALS RECOMMENDED.
strapping at intervals that adequately support the vent pipe.
2-3' intervals are recommended.

ELECTRICAL CONNECTIONS

26. Mount the metal junction box (included in HMFA) to the
framing near the blower base within 2' foot so the flexible
metal clad wire harness can be terminated and spliced
into the 120 Volt electrical supply. See Figure 30.
NOTE: all electrical connections must be performed by a
qualified electrician.
TO FIREPLACE
CONNECTIONS
To Fireplace
Connections
27. The electrician is responsible for performing all wiring
from the blower to the wall mounted rheostat or junction
box on right side of fireplace. The rheostat must be
mounted in a standard wall box (not included).
42929-2-0721
3" MINIMUM CLEARANCE TO
COMBUSTIBLES AND INSULATION
3" MINIMUM CLEARANCE TO COMBUSTIBLES
MATERIALS FROM FLEX VENTING
Figure 29
24" FLEXIBLE
CONDUIT
WIRE
2' Flexible Conduit
Wire Harness
HARNESS
120 VAC
POWER
120 VAC Power In
(From Rheostat
Wall Switch)
IN (FROM
SPEED
CONTROL)
Figure 30
Empire Comfort Systems Inc. • Belleville, IL
All wiring should be done by a qualified electrician,
and shall be in compliance with local codes and with
the current National Electric Code ANSI/NFPA 70
(in the U.S.), or with the current CSC22.1 Canadian
Electric Code (in Canada).
Make sure the fireplace electrical circuit is disabled
prior to working on electrical hookup.
OUTER TERMINATION INSTALLATION
28. Install the Outer Termination into the 14 - 1/2" X 14 - 1/2"
framed opening through the exterior wall of the building,
then secure with 1" long drywall screws as shown in
Figure 31.
WIRING
WARNING
WARNING
JUNCTION BOX
SPEED CONTROL
14-1/2" X 14-1/2"
14 1/2 X 141/2
EXTERIOR WALL
EXTERIOR WALL
OPENING
OPENING
Figure 31
Page 21