TOOLS/SUPPLIES NEEDED FOR HMFATV:
Electric Drill
Step Drill Bit (for
VFLB(36,48,60,72) - 1 only)
3/16" Drill Bit
1 - 1/2" Hole Saw
HMFATV INTRODUCTION
The HMFATV Television Kit is designed to automate the
operation of the HMFA Forced Air Blower, in order to protect
a wall-mounted television from heat damage while the
fireplace is in use. During normal operation the blower is
turned on and off by a snap-disc inside the firebox. In the
case of a power outage or blower failure, the fireplace will
be deactivated by a wall-mounted limit switch in order to
protect the television. The rheostat control included in the
HMFA Forced Air Blower is not utilized.
CONTENTS OF HMFATV:
1. Nut, 10-24 (2 ea.)
2. Screw, 10-24 X 3/4" (2 ea.)
3. Nut, 4-40 (2 ea.)
4. Screw, 4-40 X 3/4" (2 ea.)
5. Limit Switch Plate (1 ea.)
6. J-box Cover Plate (1 ea.)
7. Limit Switch, 150 degree (1 ea.)
8. Snap-Disc, 110 Close; 90 Open (1 ea.)
9. Wire Harness, Limit Switch (1 ea.)
10. Wire Harness, Fan Control (1 ea.)
11. Junction Box (1 ea.)
12. Wire Bushing, 5/8" (2 ea.)
13. Clip, Wire (2 ea.)
14. Romex Connector, 3/8" (1 ea.)
15. Zip Tie (4 ea.)
HMFA Blower MUST be mounted on an exterior wall.
DO NOT transfer heat to an interior space.
42929-2-0721
HMFATV TELEVISION KIT
Phillips Screw Driver
5/16" Nut Driver
Wall Anchors with #8
Screws (2)
Wire Nuts (2)
WARNING
Empire Comfort Systems Inc. • Belleville, IL
14. Insert the included 5/8" Wire Bushings into the two
holes called out by white arrows in Figure 16.
15. The Limit Switch Wire Harness consists of two white
wires with connectors on both ends. Route the
Limit Switch Wire Harness as shown in Figure 16,
passing through the Wire Bushings and fastened to
the HMFA-P duct with zip ties (included) called out
by the black arrows. The Wire Harness end with two
female connectors should exit through the hole in the
noncombustible board as shown. Position the Wire
Harness such that 8-9" of length is hanging out of the
noncombustible board.
16. The Limit Switch Wire Harness enters the fireplace
through the Wire Bushing in the access panel on the
left-hand side.
17. Using the included (2) 4-40 machine screws, (2) 4-40
nuts, Limit Switch Plate, and the 150 degree manually
resettable Limit Switch, assemble the Limit Switch &
Plate Assembly as shown in Figures 17 and 18 and
connect it to the Limit Switch Wire Harness.
HMFA(36,48,60,72)P Heat Transfer Kit.
Figure 16
Page 13