Design And Installation Positions - Bosch Rexroth MSK030B-0900-NN Project Planning Manual

Synchronous servomotors
Hide thumbs Also See for Rexroth MSK030B-0900-NN:
Table of Contents

Advertisement

208/279
Bosch Rexroth AG
Operating conditions and application notes
9.3

Design and installation positions

Foot assembly
Motor design B05
IM B5
IM V1
Flange attachment on
Flange attachment on
the drive side of the
the drive side of the
flange, drive side fac‐
flange
ing down
Tab. 9-7:
Permissible conditions of installation according to EN 60034-7:1993
NOTICE
If motors are attached according to IM V3, fluid present at the output shaft
over a prolonged time may penetrate and cause damage to the motors.
Ensure that fluid cannot be present at the output shaft.
In contrast to flange assembly, radial forces may only be effective in a direc‐
tion perpendicular to the mounting surface (± 15°) if foot assembly is selec‐
ted. The transmission of forces in other effective directions is not allowed.
Mounting feet
Fig. 9-3:
Foot assembly
DOK-MOTOR*-MSK********-PR12-EN-P
Synchronous Servomotors MSK
IM V3
Flange attachment on
the drive side of the
flange, drive side fac‐
ing up
Motor damage due to penetration of liquids!
IM B35
Flange attachment on
the drive side of the
flange or foot attach‐
ment

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth msk030c-0900-nnRexroth msk040b-0450-nnRexroth msk040b-0600-nnRexroth msk040c-0450-nnRexroth msk040c-0600-nnRexroth msk043c-0600-nn ... Show all

Table of Contents