Degree Of Protection - Bosch Rexroth MSK030B-0900-NN Project Planning Manual

Synchronous servomotors
Hide thumbs Also See for Rexroth MSK030B-0900-NN:
Table of Contents

Advertisement

DOK-MOTOR*-MSK********-PR12-EN-P
Synchronous Servomotors MSK
9.2

Degree of protection

The protection type according to EN 60034-5 is determined by the abbrevia‐
tion IP (International Protection) and two code numbers for the degree of pro‐
tection. The first code number describes the degree of protection against
contact with and ingress of foreign bodies, the second code number de‐
scribes the degree of protection against ingress of water.
first code number
Degree of protection
Protection against penetration of dust (dust-proof); complete contact
6
protection
Protection against ingress of solid foreign bodies with a diameter of
4
more than 1 mm
Protection against ingress of solid foreign bodies with a diameter of
2
more than 12.5 mm
second code number
Degree of protection
Protection against harmful effects when temporarily immersed in wa‐
7
ter.
Protection against a jet of water from a nozzle which is directed
5
against the housing from all directions (jet water)
Protection against water splashing against the housing from all direc‐
4
tions (splash water)
Tab. 9-5:
IP protection types
Motor area
Motor housing, output shaft, motor connector
when properly assembled in mated condition
Motor housing, output shaft, motor connector
when properly assembled in mated condition
and use of sealing air
Blower motor and connector in mated condi‐
tion
Fan grille
Output shaft with shaft sealing ring
Connector for performance and encoder connection (optionally
retrofittable for sealing air connection)
Blower motor with connector
Fan grille
Tab. 9-6:
IP protection type ranges for MSK motors
The tests for the second code number are carried out with fresh water. If
cleaning processes with high pressure and/or solvents, cooling lubricants or
creep oils are used, a higher degree of protection may be required.
Bosch Rexroth AG
Operating conditions and application notes
Degree of protec‐
tion
IP 65
Standard version
Only with sealing air ac‐
approx. IP67
IP 65
Blower unit accessories
IP 24
Blower unit accessories
207/279
Note
cessories!

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth msk030c-0900-nnRexroth msk040b-0450-nnRexroth msk040b-0600-nnRexroth msk040c-0450-nnRexroth msk040c-0600-nnRexroth msk043c-0600-nn ... Show all