190/279
Bosch Rexroth AG
Accessories
SUP-M02-MSK
Screw the encoder connector cover with sealing air connection onto the
motor. Tightening torque of the screws 1.3 Nm.
5. Connect the compressed air ‑quick coupling from the accessory kit to
the regulated compressed air source.
The sealing air unit is now ready for operation.
Fig. 7-6:
RLS1300 with sealing air connection
DANGER
Only open the connector sockets of the motor when the system is de-ener‐
gized!
1. Open main switch
2. Secure the main switch against being switched on again
3. Loosen the power connector cover screws and remove the cover.
4. Mount the sealing air connection
When fitting the cover, make sure that no cable core or seal is
damaged.
Screw the power connector cover with sealing air connection onto the
motor. Tightening torque of the screws 3.1 Nm.
5. Connect the compressed air ‑quick coupling from the accessory kit to
the regulated compressed air source.
The sealing air unit is now ready for operation.
DOK-MOTOR*-MSK********-PR12-EN-P
Synchronous Servomotors MSK
Fatal electric shock from live parts with more
than 50V!