• Identify live conductors.
• Detect residual or induced voltage.
DEVICE SPECIFICATIONS
Size
Power System
Charging
Directional Accuracy
Detection Sensitivity
Operating Frequency
Operating Conditions
Water Resistance
Detection Voltage Ranges
Case Ratings
(Polycarbonate)
Certifications
Standards
sales@safeguardequipment.com

PRIMARY FUNCTIONS

• Find energized lines underground or behind non-ferrous material.
• Detect energized threats after accidents, disasters, and power outages.
3.5"x1.2"x.04" (88.9 mm x 30.48 mm x 10.16 mm)-Body. Wt: 0.5 oz (14.2 g)
Rechargeable Lithium-Polymer (LiPo) Battery (3.7V, 250mAh). Discharge rate
varies depending on number of alerts, full charge can last 10+ days (80+ hrs)
Typically charges to 100% in 1.5 hrs on a USB 2.0 Micro B (5V) charger
Point source: Approximately ±20°
Seven sensitivity levels + Smart Adaptive mode (see page 7)
50 Hz and 60 Hz options are available
20°C to 60°C (-4°F to 140°F): DO NOT charge Compass if <0°C (32°F) RH:
Max. 90% Non-Condensing @25°C.
Rated IP-67
High Voltage Model: 2400VAC-35kVAC RMS Line to Neutral, up to 500 kVAC
Low Voltage Model: 120 VAC – 2400VAC RMS Line to Neutral
*Detection distances vary depending on conditions, settings, and model.
Flame Retardant: UL recognition 94 V-0 at 1.5 mm
Electric Strength (IEC 60243-1): 35kV/mm
Electric Volume Resistivity (IEC 60093): 1.0E+14 ohms*m
CE (ROHS, WEEE, 2006/66/EU Battery Directive)
EMC: EN 61326-1: 2013 Class B, CISPR 11:2015+A1:2016 Emissions and
Immunity for Measurement Equipment.
Safety: EN 61010-1: Safety Requirements for Electrical Equipment for
Measurement, Control, and Laboratory Use.
IEC TR 61243-6 (Type I) Guidelines on non-contact voltage detectors
(NCVD) for use at nominal voltages above 1kV AC.
ANSI/ISEA Z89.1-2014 Class E Hard Hat, Full Brim, Type 1; Tested
Accessory.
Voltage Detectors: ASTM F3283 / F3283M –18; Standard Specification
for the Manufacturing of High-Voltage Proximity Alarm to be used for the
Detection of Overhead High Voltage Alternating Current (AC).