SMART ADAPTIVE MODE
Smart Adaptive Mode is designed for users working in an environment where electric and magnetic fields are
known to be present. C
OMPASS®
closer to a detected source. If the user then moves closer to the detected source, alerts will begin again.
C
will adjust to a constant field after 5 seconds and alerts will pause automatically.
OMPASS®
You do not need to press the button to adjust sensitivity once you have entered Smart Adaptive mode.
The corner LEDs will periodically flash YELLOW once C
mind that this means that a field strong enough to normally trigger an alert is still nearby.
If the user moves away from the energized source and the field strength is reduced for approximately 5 seconds,
C
will re-adjust and regain sensitivity, indicated by corner LEDs flashing BLUE.
OMPASS®
WARNING:
MAXIMIZING ALERT ACCURACY
When using C
, always be aware of potential variables that could affect the accuracy of alerts:
OMPASS®
Warning distances can vary due to a live conductor's exposed surface area, elevation above ground, and
proximity to any other grounded conductive objects.
If the user is walking briskly, this may reduce initial warning distances by approximately two (2) feet.
Warning distances can be reduced by large conductive objects such as a fence or vehicle as these objectS will
attract the electric field of a nearby energized conductor.
3-phase systems can hinder detection accuracy by creating electric fields that effectively cancel out their overall
field strength.
Humid conditions will reduce detection distance.
Always verify C
OMPASS®
Smart Adaptive Mode should be used only by experienced electrical professionals.
sales@safeguardequipment.com
can quickly adapt to the ambient fields and pause alerts if the user is not moving
Smart Adaptive alerts are based on change in ambient electric or magnetic fields,
not proximity to the source. Alerts may not occur within the OSHA Minimum
Approach Distance (MAD) in this mode.
will function in each work environment before relying on it as a safety device.
208-773-9263
has adjusted to an environment, but keep in