Target network
address
Local MAC address
Target MAC address
Device type
Channel
Transmitting mode
Output mode
TX power
Remote configuration
ID
Local network
group number
Target network
group number
Network opening time
Reconnection cycle
when the parent node
is lost
Maximum number of
reconnections
Copyright ©2012–2017, 成都亿佰特电子科技有限公司
Read/Write
0x0000~0xFFFF
Read
64bitMAC
Read/Write
64bitMAC
Read/Write
C、R、E、S
Read/Write
CH11~26
Read/Write
0、1、2、3
Read/Write
0、1、2、3、4、
5
Read/Write
0~20dbm
Read/Write
2 bytes
Read/Write
0~255
Read/Write
0~255
Read/Write
10~2540 second
Read/Write
1~255 minute
Read/Write
1~255 次
Current device communication target (short address),
which can be switched at any time through commands
The factory default MAC address of the module which
cannot be changed by the user
Send data using long address in fixed mode
They are: coordinator, router, non-dormant terminal,
dormant terminal
Working physical channel of ZIGBEE device
Module transmitting modes: broadcast mode, multicast
mode, short address unicast mode, long address unicast mode
For details, please refer to the corresponding mode
introduction.
The data output modes of the module are:
Transparent transmission;
Data+short address;
Data+long address;
Data+RSSI;
Data+short address+RSSI;
Data+long address+RSSI
Output power of the module: 0 to 20dbm. Where power
consumption is required and the distance is not required, the tx
power can be reduced for saving average power consumption.
It is used to judge whether the data received in the air is a
remote configuration command. Customers can change the
wireless configuration ID according to their needs. The default
is A8 8A。
It is used to configure the group number of the device in
the network.
It is used to configure the group number of the
corresponding target in multicast mode.
It is used to configure the opening and closing of network
security. Devices can join the network during opening, and
devices cannot join during closing.
When the parent node is lost (coordinator is powered off),
the terminal device reconnects to the previous network at
regular intervals.
It is the maximum number of reconnections after the parent
node is lost. If the reconnection is not successful, the previous
network information is cleared and the new network is
rescanned. The scanning cycle is equal to the reconnection