6.1.2 RUN description

RUN pin indicates the current working status of the device. When the RUN light is off, it indicates that the device is
busy; when the RUN light is on, it indicates that the device is idle; when the device receives data, the RUN light goes off
for 2 to 4 ms, and the serial port starts to output data.

6.1.3 UART_BAUD_RESET description

UART_BAUD_RESET is used to reset the device baud rate. Press and hold for more than 1s to reset the radio baud
rate (115200), 8N1.

6.2 Wireless remote configuration function

The module supports the remote configuration function. The two-byte wireless configuration ID defaults to A8 8A.
The user can modify the remote configuration ID of the module. When the first two bytes of the wireless data received
by the module are the wireless configuration ID, The module will recognize the data packet as a remote configuration
command and perform the corresponding command operation. The data packet will not be output through the serial port.

6.3 Function parameter description

The module provides abundant configurable parameters, which can be flexibly used according to actual application
requirements to build different forms of networks.
Configuration
information
PANID
Local network
address
Network status
Copyright ©2012–2017, 成都亿佰特电子科技有限公司
Attributes
Parameter
range
Read/Write
0x0000~0xFFFF
Read
0x0000~0xFFFF
Read
0、1、2、3、4
Description
PANID is the identifier of the ZIGBEE network and is used
to determine the identity of the network to which it belongs. All
devices in the same network must have the same PANID. When
the terminal or router is configured as 0xFFFF, it can be added
to any network that already exists on the same channel.
It is used to distinguish each node in the network. When
each device is in the same network, the local network address
must be unique. When not connected to the network, the
device's network address is 0xFFFF. After joining the network,
the short address of the device is assigned by the coordinator .
The coordinator address is fixed: 0x0000.
Represents the network status of the current device: no
network, currently joining the network, has successfully joined
the network, has a network but has lost its parent node, is
leaving the current network, etc.