Permanent Connection

In the case of a permanent connection, it is necessary that you install
a double pole switch between the hob and the electricity supply
(mains), with a minimum gap of 3 mm. between the switch contacts
and of a type suitable for the required load in compliance with the
current electric regulations.
The switch must not break the yellow and green earth cable at any
point.
Ensure that the hob supply cord does not come into contact with
surfaces with temperatures higher than 50 deg. C.

Supply Cable Specifications

For Uk use only
Connection
via
• Cooker
Control
Circuit
For Europe use only
Min. size Cable/flex
2.5 mm
2
Min. size
Cable / flex Fuse
Cable/flex
type
6 mm
2
PVC/PVC
twin and
earth
Cable / flex type
H05 RR-F
30 A
Fuse
30 A
19