Thyracont VSR53MV Operating Instructions Manual

Thyracont VSR53MV Operating Instructions Manual

Vacuum transducer
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

V a c u u m
I n s t r u m e n t s
VSR53MV, VSR54MV
Vakuum Transmitter
Vacuum Transducer
Betriebsanleitung
Operating Instructions

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VSR53MV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thyracont VSR53MV

  • Page 1 V a c u u m I n s t r u m e n t s VSR53MV, VSR54MV Vakuum Transmitter Vacuum Transducer Betriebsanleitung Operating Instructions...
  • Page 3: Table Of Contents

    3.3 Elektrischer Anschluss ......3.3.1 Anschluss an Thyracont Anzeigegeräte ... .
  • Page 4: Hinweise Für Ihre Sicherheit

    1 Hinweise für Ihre Sicherheit Lesen und befolgen Sie alle Punkte dieser Anleitung Informieren Sie sich über Gefahren, die vom Gerät ausgehen und Gefahren, die von Ihrer Anlage ausgehen Beachten Sie die Sicherheits- und Unfall-Verhütungsvorschriften Prüfen Sie regelmäßig die Einhaltung aller Schutzmaßnahmen Installieren Sie das VSR unter Einhaltung der entsprechenden Umgebungsbedingun- gen;...
  • Page 5: Vakuum Transmitter Vsr

    2 Vakuum Transmitter VSR 2.1 Zur Orientierung Diese Betriebsanleitung ist gültig für Produkte mit den Artikelnummern VSR53MV, VSR54MV. Sie finden die Artikelnummern auf dem Typenschild. Technische Änderungen oh- ne vorherige Anzeige sind vorbehalten. 2.2 Lieferumfang Zum Lieferumfang gehören: Transmitter VSR...
  • Page 6: Produktbeschreibung

    2.3 Produktbeschreibung Der Vakuum Transmitter VSR dient zur Absolutdruck-Messung in gasförmigen Me- dien im Bereich 5,0x10 - 2000 mbar. Das Gerät kann an ein Thyracont Anzeige- gerät angeschlossen oder gemäß Anschlussbelegung mit einer kundeneigenen Spannungsversorgung betrieben werden. Das analoge Mess-Signal 1,2 V - 8,8 V ist dabei über den gesamten Messbereich logarithmisch vom Druck abhängig.
  • Page 7: Installation

    3 Installation 3.1 Hinweise zur Installation Keine eigenmächtigen Umbauten oder Veränderungen am Gerät vornehmen! Aufstellungsort: Innenräume Für nicht vollklimatisierte Betriebsräume gilt: Temperatur: +5 C ... +60 C Rel. Luftfeuchte: max. 80% bis 30 C, max. 50% bei 40 C, nicht betauend Luftdruck: 860 - 1060 hPa (mbar) 3.2 Vakuumanschluss Schmutz und Beschädigungen, insbesondere am Flansch, beein-...
  • Page 8: Elektrischer Anschluss

    Druck nicht mehr standhalten. Dies kann zu Gesundheitsschäden durch ausströmende Prozessmedien führen! 3.3 Elektrischer Anschluss 3.3.1 Anschluss an Thyracont Anzeigegeräte Wird der Transmitter an einem Thyracont Anzeigegerät betrieben, ist ein geeigne- tes Messkabel zu verwenden (siehe Zubehör). Anschluss des Transmitters niemals mit Spannung führendem Ka- bel herstellen! Stecker am Transmitter einstecken und mit Schrauben sichern.
  • Page 9: Kundeneigene Spannungsversorgung

    3.3.2 Kundeneigene Spannungsversorgung Der Transmitter kann auch mit anderen Anzeigegeräten oder kundeneigener Span- nungsversorgung betrieben werden. Die elektrische Verbindung ist unter Verwendung geeigneter Kabel EMV-gerecht gemäß untenstehender Pinbelegung herzustellen: Stecker Hirschmann, 6polig, männlich Pin1: Identifikation: 12 k Pin2: Signal Output 0-10 VDC Pin3: AGND Pin4:...
  • Page 10: Betrieb

    4 Betrieb 4.1 Allgemeines Messprinzip Vakuum Transmitter des Typs VSR besitzen eine interne Kombination aus einem piezoresistiven Membransensor und einem Piranisensor, der die Wärmeleitfähig- keit von Gasen zur Vakuummessung nutzt. Unter Einwirkung des Druckes verformt sich die dünne Membran des Piezosen- sors, auf deren Rückseite eine Widerstands-Messbrücke aufgebracht ist.
  • Page 11: Nachjustieren

    4.2 Nachjustieren Das Gerät ist ab Werk bei Versorgungsspannung 24 V stehend, d.h. mit dem Flansch nach unten, abgeglichen. Andere Einbaulagen, Einsatz unter anderen kli- matischen Bedingungen, extreme Temperaturschwankungen, Alterung oder Ver- schmutzung können ein Nachjustieren erforderlich machen. Um optimale Ergebnisse beim Nachjustieren zu erzielen, empfeh- len wir vor jedem Abgleich eine Warmlaufphase von mindestens 15 Minuten beim jeweiligen Kalibrierdruck zu beachten.
  • Page 12: Wartung Und Service

    5 Wartung und Service Vorsicht bei kontaminierten Teilen! Es kann zu Gesundheitsschäden kommen. Informieren Sie sich vor Aufnahme der Arbeiten über eine eventuelle Kontamination. Be- achten Sie beim Umgang mit kontaminierten Teilen die einschlägi- gen Vorschriften und Schutzmaßnahmen. Das Gerät ist wartungsfrei. Äußerliche Verschmutzungen können mit einem feuch- ten Tuch beseitigt werden.
  • Page 13 VSR-0-10 V-210805...
  • Page 14: Technische Daten

    6 Technische Daten Messprinzip Piezoresistiv / Wärmeleitfähigkeit Pirani (Pirani gasartabhängig) Messbereich 2000 - 5,0x10 mbar (1500 - 5,0x10 Torr) Max. Überlast 10 bar abs. Genauigkeit 2000 ... 200 mbar: 2% v. Messwert 200 ... 40 mbar: 5% v. Messwert 40 ... 1,0x10 mbar: 10% v.
  • Page 15 Schutzart IP 40 Gewicht ca. 100 g (VSR53) VSR-0-10 V-210805...
  • Page 16: Konformitätserklärung

    7 Konformitätserklärung VSR-0-10 V-210805...
  • Page 17 3.3 Electrical Connection ......3.3.1 Operation with Thyracont Display Unit ... . .
  • Page 18: Safety Instructions

    1 Safety Instructions Read and follow the instructions of this manual Inform yourself regarding hazards, which can be caused by the product or arise in your system Comply with all safety instructions and regulations for accident prevention Check regularly that all safety requirements are being complied with Take account of the ambient conditions when installing your VSR;...
  • Page 19: Vacuum Transducer Vsr

    2 Vacuum Transducer VSR 2.1 For Orientation These operating instructions describe installation and operation of products with article numbers VSR53MV, VSR54MV. The article number can be found on the product’s type label. Technical modificati- ons are reserved without prior notification. 2.2 Delivery Content...
  • Page 20: Product Description

    The VSR vacuum transducer is measuring total gas pressure in the range of 5.0x10 - 2000 mbar. The transducer can be connected to Thyracont display and control units or to customer related power supply and evaluation units in complian- ce with pin assignment.
  • Page 21: Installation

    3 Installation 3.1 Notes for Installation Unauthorized modifications or conversions of the instrument are not allowed! Installation location: Indoor For not fully air conditioned open buildings and operation rooms: Temperature: +5 C ... +60 C Rel. humidity: max. 80% up to 30 C, max. 50% at 40 C, non-condensing Ambient pressure: 860 - 1060 hPa (mbar) 3.2 Vacuum Connection Dirt and damage, especially at the vacuum flange, have an adver-...
  • Page 22: Electrical Connection

    3.3 Electrical Connection 3.3.1 Operation with Thyracont Display Unit For operation of the transducer with a Thyracont display and control unit a suitable measurement cable must be used (see accessories). Do not connect or disconnect the transducer when the cable is on circuit! Connect the cables plug to the transducer and secure it with the screw.
  • Page 23: Operation With Other Supply And Evaluation Units

    3.3.2 Operation with other Supply and Evaluation Units The transducer can be operated with other customer related display units or volta- ge supplies. The electrical connection is to be made by means of suitable cables considering EMI demands and according to the pin description shown below: Socket Hirschmann, 6pole, male Pin1:...
  • Page 24: Operation

    4 Operation 4.1 General Measurement Principle VSR vacuum transducers are equipped with an internal combination sensor of ty- pe Piezo / Pirani. Under the influence of pressure the thin diaphragm of the piezo-resistive sensor is bent, on the back of which a resistor-bridge is applied. The bending forces the measuring bridge to come out of tune, which is a measure for the applied pressure.
  • Page 25: Readjustment

    4.2 Readjustment The transducer is adjusted ex works with 24 V voltage supply in upright position, flange to the bottom. Other orientation, operation under different climatic conditi- ons, extreme temperature changes, ageing or contamination can result in the need for readjustment. To achieve optimum results of the adjustment we recommend to consider a warm-up of at least 15 minutes at the appropriate cali- bration pressure before any adjustment.
  • Page 26: Maintenance And Service

    5 Maintenance and Service Danger of possibly contaminated parts! Contaminated parts can cause personal injuries. Inform yourself regarding possible contamination before you start working. Be su- re to follow the relevant instructions and take care of necessary protective measures. The unit requires no maintenance. External dirt and soiling can be removed by a damp cloth.
  • Page 27 VSR-0-10 V-210805...
  • Page 28: Technical Data

    6 Technical Data Measurement principle piezo-resistive / heat conduction Pirani (Pirani depending on gas type) Measuring range 2000 - 5.0x10 mbar (1500 - 5.0x10 Torr) Max. overload 10 bar abs. Accuracy 2000 ... 200 mbar: 2% f. reading 200 ... 40 mbar: 5% f. reading 40 ...
  • Page 29 Protection class IP 40 Weight approx. 100 g (VSR53) VSR-0-10 V-210805...
  • Page 30: Declaration Of Conformity

    7 Declaration of Conformity VSR-0-10 V-210805...
  • Page 31 VSR-0-10 V-210805...
  • Page 32 VSR-0-10 V-210805...